New strategy of dc electrical arc furnace converter for mitigation of voltage fluctuations and comparative flicker voltage in ac and DC furnaces
المؤلفون المشاركون
Husayni-Fayruz, M.
Mozafari, B.
المصدر
العدد
المجلد 7، العدد 2 (30 يونيو/حزيران 2011)، ص ص. 149-164، 16ص.
الناشر
تاريخ النشر
2011-06-30
دولة النشر
الجزائر
عدد الصفحات
16
التخصصات الرئيسية
العلوم الهندسية والتكنولوجية (متداخلة التخصصات)
الموضوعات
الملخص EN
A novel method to mitigate voltage flicker problem usually caused by DC Arc Furnaces has been presented in this paper.
This method called Direct Current Ripple Re-injection is applied to a multi-step switching reactor in the output of the AC / DC converter to make the output load current as smoother as possible.
This method would lessen harmonic effects properly.
The proposed approach is simulated by MATLAB-SIMULINK software.
Simulation are performed using dynamic arc model in which the performance of AC and DC electric Furnaces are evaluated with respect to generation of voltage flicker on power common coupling (PCC) bulbar.
Voltage flicker level is measured by means of a standard pseudo flicker meter whose components and block diagrams are illustrated in this paper.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Husayni-Fayruz, M.& Mozafari, B.. 2011. New strategy of dc electrical arc furnace converter for mitigation of voltage fluctuations and comparative flicker voltage in ac and DC furnaces. Journal of Electrical Systems،Vol. 7, no. 2, pp.149-164.
https://search.emarefa.net/detail/BIM-291077
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Husayni-Fayruz, M.& Mozafari, B.. New strategy of dc electrical arc furnace converter for mitigation of voltage fluctuations and comparative flicker voltage in ac and DC furnaces. Journal of Electrical Systems Vol. 7, no. 2 (Jun. 2011), pp.149-164.
https://search.emarefa.net/detail/BIM-291077
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Husayni-Fayruz, M.& Mozafari, B.. New strategy of dc electrical arc furnace converter for mitigation of voltage fluctuations and comparative flicker voltage in ac and DC furnaces. Journal of Electrical Systems. 2011. Vol. 7, no. 2, pp.149-164.
https://search.emarefa.net/detail/BIM-291077
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 164
رقم السجل
BIM-291077
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر