Ru106 Brachytherapy for Management of Choroidal Melanoma : Do we Need to Adjust Total dose According to the New NIST Calibration Measurement?
المؤلفون المشاركون
Lutayf, Muhammad M.
Uthman, Ihab S.
Shelil, Abd Allah E.
Karimah, Hatim
المصدر
Journal of the Egyptian National Cancer Institute
العدد
المجلد 17، العدد 3 (30 سبتمبر/أيلول 2005)، ص ص. 211-217، 7ص.
الناشر
جامعة القاهرة المعهد القومي للأورام
تاريخ النشر
2005-09-30
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الموضوعات
الملخص EN
Purpose: To detect the need of adjusting the apical total dose according to the new NIST calibration measurement introduced by BEBIG Isotopen und Medizintechnik GmbH for the treatment of choroidal melanoma.
As the total radiation dose should not be individualized depending on errors pf previous calibration but can be applicable if based on a radiosensitivity test that was able to predict the final response of tumor to radiation for each particular patient. Patients and Methods: Twenty patients with choroidal melanomas were treated between November 2002 and July 2004 at "Suzanne Mubarak Eye Tumor Centre", National Eye centre Rod-EL Farag, Cairo, Egypt.
The prescribed dose was calculated according to the new NISTcalibrated dosimetry introduced by BEBIG, but without dose modification by using a conversion factor F(type,z) from the ASMW calibrated measurement to the NIST calibrated measurement that have been calculated depending on the plaque type and the distance z from the inner concave plaque surface along the central axis.
For the treatment of choroidal melanoma in this study the apical dose ranged from 9000-10400cGy with a mean of 9855± 385. Results: After a follow up period from 12-28 months (median of 19 months) there was a local control rate of 100 % and the three years actuarial disease specific survival was 95% as only one patient died of liver metastases. Fourteen patients had a best corrected pre-treatment visual acuity of better than 6/60 in the affected eye.
At the last follow up available, useful visual acuity of >0.5 was preserved in 7 of the patients. Conclusion: Recalculation of the apical total dose (mostly increasing of the total dose) according to the conversion factor F(type,z), suggested by BEBIG after the new NIST calibration measurement, does not seem to have an effect on both local control and survival, in this study.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Lutayf, Muhammad M.& Uthman, Ihab S.& Shelil, Abd Allah E.& Karimah, Hatim& F. R. C. S. 2005. Ru106 Brachytherapy for Management of Choroidal Melanoma : Do we Need to Adjust Total dose According to the New NIST Calibration Measurement?. Journal of the Egyptian National Cancer Institute،Vol. 17, no. 3, pp.211-217.
https://search.emarefa.net/detail/BIM-29834
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Lutayf, Muhammad M.…[et al.]. Ru106 Brachytherapy for Management of Choroidal Melanoma : Do we Need to Adjust Total dose According to the New NIST Calibration Measurement?. Journal of the Egyptian National Cancer Institute Vol. 17, no. 3 (Sep. 2005), pp.211-217.
https://search.emarefa.net/detail/BIM-29834
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Lutayf, Muhammad M.& Uthman, Ihab S.& Shelil, Abd Allah E.& Karimah, Hatim& F. R. C. S. Ru106 Brachytherapy for Management of Choroidal Melanoma : Do we Need to Adjust Total dose According to the New NIST Calibration Measurement?. Journal of the Egyptian National Cancer Institute. 2005. Vol. 17, no. 3, pp.211-217.
https://search.emarefa.net/detail/BIM-29834
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical References : p. 217
رقم السجل
BIM-29834
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)