Kinematic analysis of smart structure two links semi-lexible robot
مقدم أطروحة جامعية
al-Khafaji, Husayn Muhammad Husayn
مشرف أطروحة جامعية
الجامعة
الجامعة التكنولوجية
الكلية
-
القسم الأكاديمي
قسم الهندسة الكهروميكانيكية
دولة الجامعة
العراق
الدرجة العلمية
دكتوراه
تاريخ الدرجة العلمية
2011
الملخص الإنجليزي
-This study proposed the using of a smart structure principle with a methodology for reducing the difference (error) between the actual position (for semi-flexible robot) and the theoretically calculated position (for rigid robot) online.
The proposed methodology depends on the interfering between the maps of the two cases; the rigid case (ideal), and the deformed case (actual).
According to this methodology a class (program) was built using the visual basic.net, this class called the compensation class.
In this work, a two degrees of freedom articulated type lightweight semiflexible robot is used.
This robot is confined to move in a vertical plane.
The sensors for measuring the error deformation variables are mounted on the two links of the robot to represent with Data acquisition (DAQ) system and the actuators of the joints the smart structure system.
The smart structure robot systems are designed and built in this work.
Also, to control the smart structure robot’s systems software was built using Visual Basic.Net.
A kinematic model based on the joint angles and arm’s deflections of the two degrees of freedom is presented without simplifying the deflection’s variables.
The presence of error deformation variables in the kinematic model make the solving of the problem of inverse kinematic equation more difficult.
So, a neural network method was proposed for finding the relation between the angles of the two actuators with the end effector position and with error deformation variables.
The training showed a good fitting between the output results of the neural network and the targets data (the two angles of robot); Where the roots square error were (0.999742) and (0.999804) for the first and the second angles, respectively.
The result of the neural network has been used in the compensation class.
The experimental works is divided into two parts.
The first part is for checking the system and making the calibrations.
And, the second part is for measuring the deflection variables which are used in the kinematic model to compute the end-effector position in x and y directions.
For the measuring the endeffector position practically, the Bytescout Graph Digitizer Scout software was suggested to analyze the photos that were taken for end-effector’s path that drawn on scalar board.
The measured deformation variables in addition to the endeffector position are used as input data to the neural network for training.
Compensation tests have been done on the complete system to check the performance and results of the compensation system.
This system showed a good improvement in the performance of robot for compensation and reduction in the error between the ideal position (rigid robot) and the practical position (measured position).
The average error after the compensation reduced to 12.32 times in the x-direction and 21.76 times in the y-direction.
التخصصات الرئيسية
الموضوعات
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
al-Khafaji, Husayn Muhammad Husayn. (2011). Kinematic analysis of smart structure two links semi-lexible robot. (Doctoral dissertations Theses and Dissertations Master). University of Technology, Iraq
https://search.emarefa.net/detail/BIM-305093
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
al-Khafaji, Husayn Muhammad Husayn. Kinematic analysis of smart structure two links semi-lexible robot. (Doctoral dissertations Theses and Dissertations Master). University of Technology. (2011).
https://search.emarefa.net/detail/BIM-305093
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
al-Khafaji, Husayn Muhammad Husayn. (2011). Kinematic analysis of smart structure two links semi-lexible robot. (Doctoral dissertations Theses and Dissertations Master). University of Technology, Iraq
https://search.emarefa.net/detail/BIM-305093
لغة النص
الإنجليزية
نوع البيانات
رسائل جامعية
رقم السجل
BIM-305093
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر