An experimental study for the effect of vertical forced vibration on pool boiling heat transfer coefficient

مقدم أطروحة جامعية

Abd, Sarah Ali

مشرف أطروحة جامعية

Muhammad, Ahmad A.
Kazim, Zaynah K.

الجامعة

الجامعة التكنولوجية

الكلية

-

القسم الأكاديمي

قسم الهندسة الكهروميكانيكية

دولة الجامعة

العراق

الدرجة العلمية

ماجستير

تاريخ الدرجة العلمية

2011

الملخص الإنجليزي

-In this research, an experimental study for the effect of forced vibrations on pool boiling heat transfer coefficient has been made in a glass chamber cylinder shape (75 mm bore and 300 mm length) and an electrical heater inside it (12 mm diameter and 80 mm length) to heat the distilled water at different values of heat flux (27.521 kW/m2-53.08 kW/m2) utilized to perform this work.

The experimental study is carried out at a range of frequency (2-40 Hz) and at a range of amplitude (1.8-3.5 mm).

The result obtained showed that the pool boiling heat transfer coefficient is increasing with increasing the vibration frequency within a range of (2-14 Hz), compared with that heat transfer without frequency.

And, the maximum enhancement ratio is about 250% at 5 Hz and q"=27.521 kW/m2, 231% at 6 Hz and q"=36.727 kW/m2, 181% at 6 Hz and q"=41.83 kW/m2 and 93% at 8 Hz and q"=53.08 kW/m2.

In general, it is found that the difference in the temperature has been maintained at the highest value of vibration frequency range of (14-40 Hz), and the value of heat transfer coefficient is significantly increasing with increasing the vibration Reynolds number (Rev).

The effect of vibration frequency has improved not only the boiling heat transfer coefficient, but also led to improve the amount of heat drawn by the cooling water (condensation) by increasing the amount of falling drops.

The following empirical relations have been obtained between the experimental heat transfer coefficient with vibration (hv) and some of important parameters, such as excess temperature (ΔTexsses) in oC, input heat flux (q") in (W/m2), and vibration frequency (f) in Hz: hv = 0.246912 × f0.16534 × ΔT -0.92429 × q"1.0727 And, the second correlation is (hv) with Reynolds vibration effect (Rev) and input heat flux (q") in (kW/m2) hv=499.747×Rev0.3576×q"-2.14.

التخصصات الرئيسية

الفيزياء

الموضوعات

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Abd, Sarah Ali. (2011). An experimental study for the effect of vertical forced vibration on pool boiling heat transfer coefficient. (Master's theses Theses and Dissertations Master). University of Technology, Iraq
https://search.emarefa.net/detail/BIM-305126

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Abd, Sarah Ali. An experimental study for the effect of vertical forced vibration on pool boiling heat transfer coefficient. (Master's theses Theses and Dissertations Master). University of Technology. (2011).
https://search.emarefa.net/detail/BIM-305126

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Abd, Sarah Ali. (2011). An experimental study for the effect of vertical forced vibration on pool boiling heat transfer coefficient. (Master's theses Theses and Dissertations Master). University of Technology, Iraq