Characteristic performance of deionized columns
المؤلفون المشاركون
Husayn, Muzaffar Y.
Kassir, Nahid W.
al-Sabti, Mathil Dayif
المصدر
Iraqi Journal of Chemical and Petroleum Engineering
العدد
المجلد 9، العدد 1 (31 مارس/آذار 2008)، ص ص. 35-43، 9ص.
الناشر
تاريخ النشر
2008-03-31
دولة النشر
العراق
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
The reclamation of makeup water is studied in terms of breakthrough time (i.
e., the leakage of the cations).
Makeup water was subjected to lab-scale ion exchangers of two types: strong acid cation and weak base anion exchanger.
The experimental investigation was directed to study the ion exchanger performance in terms of four different parameters (i.e., copper concentration, total dissolved solids (TDS), feed rate and bed depth).
Box-Wilson composite rotatable design was adopted in designing the experiments.
Breakthrough times of the effluent stream are measured in terms of copper concentration of 2 to 25 ppm, TDS concentration of 250 to 1250 ppm, feed rate of 0.38 to 5.
34 l / h and bed depth of 5 to 70 cm.
Simulation the effect of the studied variables through their pre-designed ranges in terms of breakthrough time was done by 2nd order polynomial equation.
In general, the performance and characteristic of adopting two bed deionizers (cation and anion beds) was efficiently recommended to remove the ionic contaminants and not less than 95 % of wastewater is recycled.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
al-Sabti, Mathil Dayif& Kassir, Nahid W.& Husayn, Muzaffar Y.. 2008. Characteristic performance of deionized columns. Iraqi Journal of Chemical and Petroleum Engineering،Vol. 9, no. 1, pp.35-43.
https://search.emarefa.net/detail/BIM-353876
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
al-Sabti, Mathil Dayif…[et al.]. Characteristic performance of deionized columns. Iraqi Journal of Chemical and Petroleum Engineering Vol. 9, no. 1 (Mar. 2008), pp.35-43.
https://search.emarefa.net/detail/BIM-353876
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
al-Sabti, Mathil Dayif& Kassir, Nahid W.& Husayn, Muzaffar Y.. Characteristic performance of deionized columns. Iraqi Journal of Chemical and Petroleum Engineering. 2008. Vol. 9, no. 1, pp.35-43.
https://search.emarefa.net/detail/BIM-353876
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 43
رقم السجل
BIM-353876
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر