Ultrasonic defect sizing in grey cast iron compared with steel, using the maximum echo amplitude technique
العناوين الأخرى
تقدير حجم العيوب بواسطة الموجات فوق الصوتية في حديد الصب الرمادي مقارنة بالصلب باستخدام تقنية الصدى القصوى
المؤلف
المصدر
al-Rafidain Engineering Journal
العدد
المجلد 13، العدد 2 (30 يونيو/حزيران 2005)، ص ص. 56-71، 16ص.
الناشر
تاريخ النشر
2005-06-30
دولة النشر
العراق
عدد الصفحات
16
التخصصات الرئيسية
الملخص EN
In ultrasonic defect sizing using the maximum echo amplitude technique, the reflected echo signal height is taken to be related to the amount of ultrasound propagated energy which is reflected from defects and to the information contained in this reflected energy.
In this investigation horizontal drilled holes of known sizes are considered in grey cast iron which is usually treated as the most difficult type of cast irons when ultrasonically inspected, due to its high sound attenuated nature.
The defects sizing results obtained from grey cast iron are compared with those obtained from a steel of a similar pearlitic matrix structure as a reference material.
2, 4, 6 & 8 mm drilled holes at known depths are prepared in both grey cast iron and steel test samples.
Maximum echo amplitude sizing method is adopted, using both compression wave probes & shear wave probes of 1,2,4 & 6 MHz frequencies at different scanning positions.
Although the results are only limited to defect sizing in grey cast iron with reference to steel, they do
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ibrahim, Subhi Ismail. 2005. Ultrasonic defect sizing in grey cast iron compared with steel, using the maximum echo amplitude technique. al-Rafidain Engineering Journal،Vol. 13, no. 2, pp.56-71.
https://search.emarefa.net/detail/BIM-364630
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ibrahim, Subhi Ismail. Ultrasonic defect sizing in grey cast iron compared with steel, using the maximum echo amplitude technique. al-Rafidain Engineering Journal Vol. 13, no. 2 (2005), pp.56-71.
https://search.emarefa.net/detail/BIM-364630
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ibrahim, Subhi Ismail. Ultrasonic defect sizing in grey cast iron compared with steel, using the maximum echo amplitude technique. al-Rafidain Engineering Journal. 2005. Vol. 13, no. 2, pp.56-71.
https://search.emarefa.net/detail/BIM-364630
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes appendices : p. 65-71
رقم السجل
BIM-364630
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر