Polymer coated quartz crystal microbalance sensors for the detection of volatile organic compounds

المؤلفون المشاركون

Bougharouat, Ali
Bellel, Izz al-Din
Sahli, Salah
Segui, Yvan
Raynaud, Patrice

المصدر

Journal of New Technology and Materials

العدد

المجلد 3، العدد 1 (30 يونيو/حزيران 2013)، ص ص. 8-11، 4ص.

الناشر

جامعة العربي بن مهيدي بأم البواقي

تاريخ النشر

2013-06-30

دولة النشر

الجزائر

عدد الصفحات

4

التخصصات الرئيسية

الكيمياء

الموضوعات

الملخص EN

In this work, plasma polymerization of tetraethoxysilane (TEOS) has been used for producing QCM chemical sensors.

The sensor was exposed towards the methanol and chloroform molecules.

The measured isotherms on modified QCM electrode showed a good reproducibility and reversibility.

Generally, the frequency shift (Δf) of QCM increases linearly with the vapor concentration.

The evolution of sensor response showed clearly an improvement of the QCM sensibility.

However, the film elaborated from 50 % of TEOS and 50 % of O2 was found to be significantly more sensitive than film deposited from high proportion of oxygen due to dense structure.

Concerning the selectivity, the results revealed a good affinity of the layer to methanol molecules.

Fourier transform infrared spectroscopy (FTIR) analysis showed that VOCs molecules interact via hydrogen bonding due to the presence of the-OH group in the elaborated layers.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Bougharouat, Ali& Bellel, Izz al-Din& Sahli, Salah& Segui, Yvan& Raynaud, Patrice. 2013. Polymer coated quartz crystal microbalance sensors for the detection of volatile organic compounds. Journal of New Technology and Materials،Vol. 3, no. 1, pp.8-11.
https://search.emarefa.net/detail/BIM-367601

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Bougharouat, Ali…[et al.]. Polymer coated quartz crystal microbalance sensors for the detection of volatile organic compounds. Journal of New Technology and Materials Vol. 3, no. 1 (2013), pp.8-11.
https://search.emarefa.net/detail/BIM-367601

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Bougharouat, Ali& Bellel, Izz al-Din& Sahli, Salah& Segui, Yvan& Raynaud, Patrice. Polymer coated quartz crystal microbalance sensors for the detection of volatile organic compounds. Journal of New Technology and Materials. 2013. Vol. 3, no. 1, pp.8-11.
https://search.emarefa.net/detail/BIM-367601

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 11

رقم السجل

BIM-367601