Electro-cautery versus scalpel incision in abdominal surgery
المؤلفون المشاركون
al-Mahfuz, Nizar A.
al-Abayachii, Ahmad M. Taha
المصدر
العدد
المجلد 11، العدد 1 (31 مارس/آذار 2005)6ص.
الناشر
تاريخ النشر
2005-03-31
دولة النشر
العراق
عدد الصفحات
6
التخصصات الرئيسية
الموضوعات
الملخص EN
Electrocautery is used increasingly for tissue dissection ; fears of excessive scaring and poor wound healing curtailed its use for skin incisions.
This study compared electrocautery incision with traditional scalpel incision for abdominal operations in general surgery.
Two groups of 62 patients in each were compared prospectively, in one of them electrocautery knife used and in the other traditional scalpel used to incised the abdominal wall layers starting from the skin.
Parameters measured included, the time needed to complete the incision with all the necessary hemostasis, the wound length, the macroscopic tissue response, the incidence of infection, the final tissue scar.
The electrocautery knife is quicker than the traditional scalpel 4.2Cm / Minute in electrocautery knife versus 2.7Cm / Minute in scalpel; there was little increase in macroscopic tissue response in the first 3-4 days, which do not differ in both groups in the 4th5th day.
There was no difference in the incidence of infection and the final scar after one year between the two groups.
Electrocautery can be used as alternative to scalpel in creating abdominal skin incisions, with the advantages of shortening the time, and decreasing the blood loss without affecting wound healing or incidence of infection and the scar formation.
Incidence.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
al-Mahfuz, Nizar A.& al-Abayachii, Ahmad M. Taha. 2005. Electro-cautery versus scalpel incision in abdominal surgery. Basrah Journal of Surgery،Vol. 11, no. 1.
https://search.emarefa.net/detail/BIM-386019
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
al-Mahfuz, Nizar A.& al-Abayachii, Ahmad M. Taha. Electro-cautery versus scalpel incision in abdominal surgery. Basrah Journal of Surgery Vol. 11, no. 1 (Mar. 2005).
https://search.emarefa.net/detail/BIM-386019
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
al-Mahfuz, Nizar A.& al-Abayachii, Ahmad M. Taha. Electro-cautery versus scalpel incision in abdominal surgery. Basrah Journal of Surgery. 2005. Vol. 11, no. 1.
https://search.emarefa.net/detail/BIM-386019
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-386019
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر