Comparison of different edge detections and noise reduction on ultrasound images of carotid and brachial arteries using a speckle reducing anisotropic diffusion filter

المؤلفون المشاركون

Rafati, Mehravar
Arabfard, Masud
Rahimzadah, Mehrdad Rafati

المصدر

Iranian Red Crescent Medical Journal

العدد

المجلد 16، العدد 9 (30 سبتمبر/أيلول 2014)، ص ص. 1-9، 9ص.

الناشر

المستشفى الإيراني

تاريخ النشر

2014-09-30

دولة النشر

الإمارات العربية المتحدة

عدد الصفحات

9

التخصصات الرئيسية

العلوم الطبية والصيدلة والعلوم الصحية

الملخص EN

Background : Common carotid artery (CCA) ultrasound with measurement of intima-media thickness (IMT) is a safe and noninvasive technique for assessing subclinical atherosclerosis and determining cardiovascular risks.

Moreover, the pattern of wall thickening in the brachial artery (BA) is rather diffuse compared to the carotid artery and may be a more sensitive indicator of long-term systemic exposure to risk factors.

Therefore noninvasive evaluation of mechanical parameters changes of both arteries has gained the attention of researchers. Objectives : The aim of this study was to compare different edge detection techniques with speckle reducing anisotropic diffusion (SRAD) de-noising filter in ultrasound images of both arteries. Patients and Methods : In a cross-sectional design, an examination was performed on ten men with mean age of 40 ± 5 years from September 2012 to March 2013 through random sampling.

An ultrasonic examination of the left CCA and BA was performed.

The program was designed in the MATLAB software to extract consecutive images in JPEG format from the AVI.

Another program was designed in the MATLAB software to apply regions of interest (ROI) on the IMT of the posterior wall of common carotid and brachial arteries.

Next, different edge detections and SRAD filter were applied to the ROI, separately.

Finally, the program measured mean-squared error (MSE) and peak signal to noise ratio (PSNR). Results : The lowest values of MSE and highest values of PSNR were achieved by Canny edge detection with de-noising SRAD filter for IMT of left CCA and BA in 90 frames. Conclusions : Based on the result, by measuring the MSE and PSNR, this study showed Canny edge detection with SRAD filter is better than other edge detections in terms of speckle suppression and details preservation in CCA and BA ultrasound images.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Rafati, Mehravar& Arabfard, Masud& Rahimzadah, Mehrdad Rafati. 2014. Comparison of different edge detections and noise reduction on ultrasound images of carotid and brachial arteries using a speckle reducing anisotropic diffusion filter. Iranian Red Crescent Medical Journal،Vol. 16, no. 9, pp.1-9.
https://search.emarefa.net/detail/BIM-407801

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Rafati, Mehravar…[et al.]. Comparison of different edge detections and noise reduction on ultrasound images of carotid and brachial arteries using a speckle reducing anisotropic diffusion filter. Iranian Red Crescent Medical Journal Vol. 16, no. 9 (Sep. 2014), pp.1-9.
https://search.emarefa.net/detail/BIM-407801

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Rafati, Mehravar& Arabfard, Masud& Rahimzadah, Mehrdad Rafati. Comparison of different edge detections and noise reduction on ultrasound images of carotid and brachial arteries using a speckle reducing anisotropic diffusion filter. Iranian Red Crescent Medical Journal. 2014. Vol. 16, no. 9, pp.1-9.
https://search.emarefa.net/detail/BIM-407801

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 9

رقم السجل

BIM-407801