The effect of operating conditions on pollution emission from constant pressure burner

مقدم أطروحة جامعية

Radi, Riyad Sulayman

مشرف أطروحة جامعية

Hasan, Abd al-Kazim Muhammad
Hasan, Abd al-Sattar Jawad M.

الجامعة

الجامعة التكنولوجية

الكلية

-

القسم الأكاديمي

قسم الهندسة الميكانيكية

دولة الجامعة

العراق

الدرجة العلمية

ماجستير

تاريخ الدرجة العلمية

2013

الملخص الإنجليزي

An experimental study is conducted on the influence of the operating parameters of a constant pressure burner on the emitted pollutants.

The liquid hydrocarbon fuels studied are kerosene and gas oil.

The inlet air temperature was varied from 30°C to 70°C in 10°C degree increments , atomization pressure was varied from 1 bar to 5 bar in 1 bar increments , and the local equivalence ratio was varied from 0.8 to 1.7.

The burner which is used may be made use in industrial furnace, which contain on an air-blast atomizer was designed and manufactured to generate the droplets.

The atomizer is a 0.0144 m square iron block which consists of four plain-jet atomizers distributed within square plane and the distance between them is 2cm within the block.

Each plain-jet atomizer consists of a fuel tube of 0.5 mm outside diameter and 0.3 mm inside diameter, surrounded concentrically by an air tube of 1.3 mm inside diameter.

The block consists also of nine ports for main air flowing.

Each port is 15 mm diameter.

It is found that the CO and UHC are inversely proportional to inlet air temperature.

In contrast, soot is directly proportional to inlet air temperature at constant atomization pressure and various equivalence ratios.

CO, UHC, and Soot are inversely proportional to atomization pressure at constant inlet air temperature and various equivalence ratios.

CO, UHC, and soot are directly proportional to equivalence ratio at constant atomization pressure and various inlet air temperatures.

Emissions from a constant pressure burner depend on the physical and chemical properties of fuel, such as (viscosity and surface tension, volatility, H/C ratio, lower heating value and aromatic content).

And ,it is found that the emissions from gas oil are generally more than emissions from kerosene fuel for example , when equivalence ratio increases from 0.8 to 1.7 at Tinlet = 30°C, and patomization = 2bar, changing kerosene fuel with gas oil fuel increase emissions by (18.8%, 17.5% ,10.22%) for CO ,UHC , and soot emissions, respectively.

التخصصات الرئيسية

العلوم الهندسية والتكنولوجية (متداخلة التخصصات)

الموضوعات

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Radi, Riyad Sulayman. (2013). The effect of operating conditions on pollution emission from constant pressure burner. (Master's theses Theses and Dissertations Master). University of Technology, Iraq
https://search.emarefa.net/detail/BIM-413139

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Radi, Riyad Sulayman. The effect of operating conditions on pollution emission from constant pressure burner. (Master's theses Theses and Dissertations Master). University of Technology. (2013).
https://search.emarefa.net/detail/BIM-413139

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Radi, Riyad Sulayman. (2013). The effect of operating conditions on pollution emission from constant pressure burner. (Master's theses Theses and Dissertations Master). University of Technology, Iraq