![](/images/graphics-bg.png)
Low-Noise Dynamic Reconstruction for X-Ray Tomographic Perfusion Studies Using Low Sampling Rates
المؤلفون المشاركون
المصدر
International Journal of Biomedical Imaging
العدد
المجلد 2009، العدد 2009 (31 ديسمبر/كانون الأول 2009)، ص ص. 1-13، 13ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2010-01-17
دولة النشر
مصر
عدد الصفحات
13
التخصصات الرئيسية
الملخص EN
Functional imaging based on tomographic X-ray imaging relies on the reconstruction of a temporal sequence of images which accurately reproduces the time attenuation curves of the tissue.
The main constraints of these techniques are temporal resolution and dose.
Using current techniques the data acquisition has to be performed fast so that the dynamic attenuation values can be regarded as static during the scan.
Due to the relatively high number of repeated scans the dose per single scan has to be low yielding a poor signal-to-noise ratio (SNR) in the reconstructed images.
In a previous publication a temporal interpolation scheme in the projection data space was relaxing the temporal resolution constraint.
The aim of this contribution is the improvement of the SNR.
A temporal smoothing term is introduced in the temporal interpolation scheme such that only the physiologic relevant bandwidth is considered.
A significant increase of the SNR is achieved.
The obtained level of noise only depends on the total dose applied and is independent of the number of scans and the SNR of a single reconstructed image.
The approach might be the first step towards using slowly rotating CT systems for perfusion imaging like C-arm or small animal CT scanners.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Montes, Pau& Lauritsch, Günter. 2010. Low-Noise Dynamic Reconstruction for X-Ray Tomographic Perfusion Studies Using Low Sampling Rates. International Journal of Biomedical Imaging،Vol. 2009, no. 2009, pp.1-13.
https://search.emarefa.net/detail/BIM-447028
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Montes, Pau& Lauritsch, Günter. Low-Noise Dynamic Reconstruction for X-Ray Tomographic Perfusion Studies Using Low Sampling Rates. International Journal of Biomedical Imaging No. 2009 (2009), pp.1-13.
https://search.emarefa.net/detail/BIM-447028
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Montes, Pau& Lauritsch, Günter. Low-Noise Dynamic Reconstruction for X-Ray Tomographic Perfusion Studies Using Low Sampling Rates. International Journal of Biomedical Imaging. 2010. Vol. 2009, no. 2009, pp.1-13.
https://search.emarefa.net/detail/BIM-447028
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-447028
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)