Subacute Drug-Eluting Stent Thrombosis Caused by Stent Underexpansion : Evaluation by Optical Coherence Tomography

المؤلفون المشاركون

Jiménez-Valero, Santiago
Moreno Gomez, Raul
Navarro, Felipe
Martín-Reyes, Roberto

المصدر

Case Reports in Medicine

العدد

المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-3، 3ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2011-02-23

دولة النشر

مصر

عدد الصفحات

3

التخصصات الرئيسية

الطب البشري

الملخص EN

We present the case report of a patient presenting with ST segment elevation myocardial infarction due to a subacute drug-eluting stent trombosis within the proximal segment of the left circumflex artery (LCX).

Six days before a total chronic occlusion was treated at the mid segment of the LCX by overlapping two drug-eluting stents.

Optical coherence tomography (OCT) was helpful to demonstrate stent underexpansion of the overlaping segment as the main mechanism of early stent thrombosis.

This case is illustrative about the potential role of OCT to identify the mechanisms of ST and thus guiding the PCI procedure.

Moreover, our case shows the capability of the Imagewire to cross a severe stenosis due to stent underexpansion that could not be crossed by the IVUS catheter.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Martín-Reyes, Roberto& Jiménez-Valero, Santiago& Navarro, Felipe& Moreno Gomez, Raul. 2011. Subacute Drug-Eluting Stent Thrombosis Caused by Stent Underexpansion : Evaluation by Optical Coherence Tomography. Case Reports in Medicine،Vol. 2011, no. 2011, pp.1-3.
https://search.emarefa.net/detail/BIM-447982

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Martín-Reyes, Roberto…[et al.]. Subacute Drug-Eluting Stent Thrombosis Caused by Stent Underexpansion : Evaluation by Optical Coherence Tomography. Case Reports in Medicine No. 2011 (2011), pp.1-3.
https://search.emarefa.net/detail/BIM-447982

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Martín-Reyes, Roberto& Jiménez-Valero, Santiago& Navarro, Felipe& Moreno Gomez, Raul. Subacute Drug-Eluting Stent Thrombosis Caused by Stent Underexpansion : Evaluation by Optical Coherence Tomography. Case Reports in Medicine. 2011. Vol. 2011, no. 2011, pp.1-3.
https://search.emarefa.net/detail/BIM-447982

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-447982