There has been a tremendous progress in most of the computational domains in recent times.
One of the key areas is analyzing the complex interaction of blood flow through elastic artery.
Such study will aid in predicting the progression and behaviour of diseases like atherosclerosis and hypertension.
In the present investigation, a simple straight common carotid artery having an eccentric blockage is analyzed for normal as well as high blood pressure condition.
The clinical data has been obtained from ultrasound measurements on a volunteer patient and a model is generated, ANSYS, a commercially available Finite Element Analysis software.
The ANSYS Fluid-Structure Interaction (FSI) solver is used to perform the coupled field transient analysis for three pulse cycles and the obtained results demonstrate the pulsatile flow.
The simulation shows that the influence of hypertension has high deformation than normal case, severely altering the flow dynamics in downstream of the stenosis.
The results obtained agree very well with available clinical observation of normal blood pressure condition.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Abdul Khader, S. M.& Ayachit, Anurag& Pai, B. Raghuvir& Rao, V. R. K.& Kamath, S. Ganesh. 2012. FSI Simulation of Common Carotid under Normal and High Blood Pressures. Advances in Mechanical Engineering،Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-448957
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Abdul Khader, S. M.…[et al.]. FSI Simulation of Common Carotid under Normal and High Blood Pressures. Advances in Mechanical Engineering No. 2012 (2012), pp.1-6.
https://search.emarefa.net/detail/BIM-448957
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Abdul Khader, S. M.& Ayachit, Anurag& Pai, B. Raghuvir& Rao, V. R. K.& Kamath, S. Ganesh. FSI Simulation of Common Carotid under Normal and High Blood Pressures. Advances in Mechanical Engineering. 2012. Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-448957
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-448957
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر