Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses
المؤلفون المشاركون
González-Panizo, Fernando
Levy, Michael J.
Albillos, Agustin
Vazquez-Sequeiros, Enrique
Boixeda-Miquel, Daniel
Juzgado-Lucas, Diego
Foruny-Olcina, Jose Ramon
Van Domselaar, Manuel
المصدر
Diagnostic and Therapeutic Endoscopy
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-05-30
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
Background and Aims.
EUS-FNA is an accurate and safe technique to biopsy mediastinal lymph nodes.
However, there are few data pertaining to the role of EUS-FNA to biopsy central lung masses.
The aim of the study was to assess the diagnostic yield and safety of EUS-FNA of indeterminate central mediastinal lung masses.
Methods.
Design: Retrospective review of a prospectively maintained database; noncomparative.
Setting: Tertiary referral center.
From 10/2004 to 12/2010, all patients with a lung mass located within proximity to the esophagus were referred for EUS-FNA.
Main Outcome Measurement: EUS-FNA diagnostic accuracy and safety.
Results.
73 consecutive patients were included.
EUS allowed detection in 62 (85%) patients with lack of visualization prohibiting FNA in 11 patients.
Among sampled lesions, one patient (1/62 = 1.6%) had a benign lung mass (hamartoma), while the remaining 61 patients (61/62 = 98.4%) had a malignant mass (primary lung cancer: 55/61 = 90%; lung metastasis: 6/61 = 10%).
The sensitivity, specificity, and accuracy of EUS-FNA were 96.7%, 100%, and 96.7%, respectively.
The sensitivity was 80.8% when considering nonvisualized masses.
One patient developed a pneumothorax (1/62 = 1.6%).
Conclusions.
EUS-FNA appears to be an accurate and safe technique for tissue diagnosis of central mediastinal lung masses.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Vazquez-Sequeiros, Enrique& Levy, Michael J.& Van Domselaar, Manuel& González-Panizo, Fernando& Foruny-Olcina, Jose Ramon& Boixeda-Miquel, Daniel…[et al.]. 2013. Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses. Diagnostic and Therapeutic Endoscopy،Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-449792
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Vazquez-Sequeiros, Enrique…[et al.]. Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses. Diagnostic and Therapeutic Endoscopy No. 2013 (2013), pp.1-6.
https://search.emarefa.net/detail/BIM-449792
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Vazquez-Sequeiros, Enrique& Levy, Michael J.& Van Domselaar, Manuel& González-Panizo, Fernando& Foruny-Olcina, Jose Ramon& Boixeda-Miquel, Daniel…[et al.]. Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses. Diagnostic and Therapeutic Endoscopy. 2013. Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-449792
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-449792
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر