Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses

المؤلفون المشاركون

González-Panizo, Fernando
Levy, Michael J.
Albillos, Agustin
Vazquez-Sequeiros, Enrique
Boixeda-Miquel, Daniel
Juzgado-Lucas, Diego
Foruny-Olcina, Jose Ramon
Van Domselaar, Manuel

المصدر

Diagnostic and Therapeutic Endoscopy

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-05-30

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الطب البشري

الملخص EN

Background and Aims.

EUS-FNA is an accurate and safe technique to biopsy mediastinal lymph nodes.

However, there are few data pertaining to the role of EUS-FNA to biopsy central lung masses.

The aim of the study was to assess the diagnostic yield and safety of EUS-FNA of indeterminate central mediastinal lung masses.

Methods.

Design: Retrospective review of a prospectively maintained database; noncomparative.

Setting: Tertiary referral center.

From 10/2004 to 12/2010, all patients with a lung mass located within proximity to the esophagus were referred for EUS-FNA.

Main Outcome Measurement: EUS-FNA diagnostic accuracy and safety.

Results.

73 consecutive patients were included.

EUS allowed detection in 62 (85%) patients with lack of visualization prohibiting FNA in 11 patients.

Among sampled lesions, one patient (1/62 = 1.6%) had a benign lung mass (hamartoma), while the remaining 61 patients (61/62 = 98.4%) had a malignant mass (primary lung cancer: 55/61 = 90%; lung metastasis: 6/61 = 10%).

The sensitivity, specificity, and accuracy of EUS-FNA were 96.7%, 100%, and 96.7%, respectively.

The sensitivity was 80.8% when considering nonvisualized masses.

One patient developed a pneumothorax (1/62 = 1.6%).

Conclusions.

EUS-FNA appears to be an accurate and safe technique for tissue diagnosis of central mediastinal lung masses.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Vazquez-Sequeiros, Enrique& Levy, Michael J.& Van Domselaar, Manuel& González-Panizo, Fernando& Foruny-Olcina, Jose Ramon& Boixeda-Miquel, Daniel…[et al.]. 2013. Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses. Diagnostic and Therapeutic Endoscopy،Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-449792

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Vazquez-Sequeiros, Enrique…[et al.]. Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses. Diagnostic and Therapeutic Endoscopy No. 2013 (2013), pp.1-6.
https://search.emarefa.net/detail/BIM-449792

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Vazquez-Sequeiros, Enrique& Levy, Michael J.& Van Domselaar, Manuel& González-Panizo, Fernando& Foruny-Olcina, Jose Ramon& Boixeda-Miquel, Daniel…[et al.]. Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses. Diagnostic and Therapeutic Endoscopy. 2013. Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-449792

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-449792