Limitations of the Use of Pressure Waves to Verify Correct Epidural Needle Position in Dogs

المؤلفون المشاركون

Spadavecchia, Claudia
Adami, Chiara
Bergadano, Alessandra

المصدر

Veterinary Medicine International

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-06-18

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

علم الحيوان

الملخص EN

The use of pressure waves to confirm the correct position of the epidural needle has been described in several domestic species and proposed as a valid alternative to standard methods, namely, control radiographic exam and fluoroscopy.

The object of this retrospective clinical study was to evaluate the sensitivity of the epidural pressure waves as a test to verify the correct needle placement in the epidural space in dogs, in order to determine whether this technique could be useful not only in the clinical setting but also when certain knowledge of needle’s tip position is required, for instance when performing clinical research focusing on epidural anaesthesia.

Of the 54 client-owned dogs undergoing elective surgeries and enrolled in this retrospective study, only 45% showed epidural pressure waves before and after epidural injection.

Twenty-six percent of the animals showed epidural pressure waves only after the injection, whereas 29% of the dogs showed epidural pressure waves neither before nor after injection and were defined as false negatives.

Our results show that the epidural pressure wave technique to verify epidural needle position lacks sensitivity, resulting in many false negatives.

As a consequence, the applicability of this technique is limited to situations in which precise, exact knowledge of the needle's tip position is not mandatory.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Adami, Chiara& Bergadano, Alessandra& Spadavecchia, Claudia. 2013. Limitations of the Use of Pressure Waves to Verify Correct Epidural Needle Position in Dogs. Veterinary Medicine International،Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-450580

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Adami, Chiara…[et al.]. Limitations of the Use of Pressure Waves to Verify Correct Epidural Needle Position in Dogs. Veterinary Medicine International No. 2013 (2013), pp.1-6.
https://search.emarefa.net/detail/BIM-450580

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Adami, Chiara& Bergadano, Alessandra& Spadavecchia, Claudia. Limitations of the Use of Pressure Waves to Verify Correct Epidural Needle Position in Dogs. Veterinary Medicine International. 2013. Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-450580

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-450580