Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt : Technical Note and Literature Review
المؤلفون المشاركون
Tanaka, Toshihiro
Inoue, Masayoshi
Nakagawa, Hiroyuki
Kichikawa, Kimihiko
Yoshioka, Tetsuya
المصدر
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-03-27
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
Purpose.
Interventional treatment strategies for patients with encephalopathy due to splenorenal shunt remain controversial.
Portosplenic blood flow separation by occluding the splenic vein could avoid the complication of severe portal hypertension, but it would require repeated reintervention due to recurrence of symptoms.
This paper describes occlusion of the splenic vein using coil anchors and prophylactic embolization of a collateral hepatofugal vessel with no recurrence of hyperammonemia.
Materials and Methods.
A 51-year-old woman with severe cirrhosis had hepatic encephalopathy due to a large splenorenal shunt.
The serum ammonia level was 132 μg/dL.
Via a transileocolic approach, the splenic vein was completely embolized with 0.035-inch metallic coils using coil anchors while preserving the splenorenal shunt.
In addition, one of the collateral vessels of the portal vein, the retrogastric vein, was also embolized prophylactically.
Results.
After this procedure, the serum ammonia level decreased immediately to 24 μg/dL.
The portal venous pressure increased by only 1.5 mmHg.
Hepatic encephalopathy had not been observed for 25 months after the procedure, and neither retention of ascites nor worsening of esophageal varices and liver function was observed.
Conclusion.
This procedure appears to be safe and effective for hepatic encephalopathy caused by a splenorenal shunt.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Inoue, Masayoshi& Tanaka, Toshihiro& Nakagawa, Hiroyuki& Yoshioka, Tetsuya& Kichikawa, Kimihiko. 2013. Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt : Technical Note and Literature Review. Case Reports in Radiology،Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-450679
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Inoue, Masayoshi…[et al.]. Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt : Technical Note and Literature Review. Case Reports in Radiology No. 2013 (2013), pp.1-5.
https://search.emarefa.net/detail/BIM-450679
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Inoue, Masayoshi& Tanaka, Toshihiro& Nakagawa, Hiroyuki& Yoshioka, Tetsuya& Kichikawa, Kimihiko. Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt : Technical Note and Literature Review. Case Reports in Radiology. 2013. Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-450679
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-450679
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر