As-formed and vacuum annealed zero-valent iron nanoparticles (nano-Fe0) and magnetite nanoparticles (nano-Fe3O4) were tested for the removal of uranium from carbonate-rich mine water.
Nanoparticles were introduced to batch systems containing the mine water under oxygen conditions representative of near-surface waters, with a uranyl solution studied as a simple comparator system.
Despite the vacuum annealed nano-Fe0 having a 64.6% lower surface area than the standard nano-Fe0, similar U removal (>98%) was recorded during the initial stages of reaction with the mine water.
In contrast, ≤15% U removal was recorded for the mine water treated with both as-formed and vacuum annealed nano-Fe3O4.
Over extended reaction periods (>1 week), appreciable U rerelease was recorded for the mine water solutions treated using nano-Fe0, whilst the vacuum annealed material maintained U at <50 μg L−1 until 4 weeks reaction.
XPS analysis of reacted nanoparticulate solids confirmed the partial chemical reduction of UVI to UIV in both nano-Fe0 water treatment systems, but with a greater amount of UIV detected on the vacuum annealed particles.
Results suggest that vacuum annealing can enhance the aqueous reactivity of nano-Fe0 and, for waters of complex chemistry, can improve the longevity of aqueous U removal.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Crane, R. A.& Scott, T. B.. 2013. The Effect of Vacuum Annealing of Magnetite and Zero-Valent Iron Nanoparticles on the Removal of Aqueous Uranium. Journal of Nanotechnology،Vol. 2013, no. 2013, pp.1-11.
https://search.emarefa.net/detail/BIM-451766
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Crane, R. A.& Scott, T. B.. The Effect of Vacuum Annealing of Magnetite and Zero-Valent Iron Nanoparticles on the Removal of Aqueous Uranium. Journal of Nanotechnology No. 2013 (2013), pp.1-11.
https://search.emarefa.net/detail/BIM-451766
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Crane, R. A.& Scott, T. B.. The Effect of Vacuum Annealing of Magnetite and Zero-Valent Iron Nanoparticles on the Removal of Aqueous Uranium. Journal of Nanotechnology. 2013. Vol. 2013, no. 2013, pp.1-11.
https://search.emarefa.net/detail/BIM-451766
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-451766
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر