Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device
المؤلفون المشاركون
Nißle, K.
Ecker, N.
Hannemann-Pohl, K.
Brune, T.
Garritsen, H.
المصدر
العدد
المجلد 2009، العدد 2009 (31 ديسمبر/كانون الأول 2009)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2010-02-04
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
Background.
We developed a completely closed system based on gravity separation without centrifugation steps for separation of whole blood.
With this new system we compared quality and stability of the processed blood components (PRC and plasma) with respect to classical preparation.
Furthermore the cost-effectiveness of this hollow fibre system was evaluated.
Study Design and Methods.
Whole blood collections of 15 regular blood donors were used for component preparation using the U shaped hollow fibre filter device.
Results were compared to 15 whole blood preparations using centrifugation.
The following parameters were evaluated: total hemoglobin, leukocyte counts, the serum concentration of total protein, lactate dehydrogenase (LDH) and potassium.
Furthermore ATIII, vWF and F VIII were analyzed at different timepoints.
Results.
packed red cells: the data directly after separation and after 42 days of storage are in line with the guidelines of the council of Europe.
Plasma.
all plasma quality data are in line with the guidelines of the council of Europe for quality assurance of plasma, except for a low protein amount (factor 0.75).
Conclusion.
Separation of whole blood on a clinical scale in this new closed system is feasible, however the plasma protein content must be optimized.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Brune, T.& Hannemann-Pohl, K.& Nißle, K.& Ecker, N.& Garritsen, H.. 2010. Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device. Advances in Hematology،Vol. 2009, no. 2009, pp.1-6.
https://search.emarefa.net/detail/BIM-451925
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Brune, T.…[et al.]. Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device. Advances in Hematology No. 2009 (2009), pp.1-6.
https://search.emarefa.net/detail/BIM-451925
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Brune, T.& Hannemann-Pohl, K.& Nißle, K.& Ecker, N.& Garritsen, H.. Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device. Advances in Hematology. 2010. Vol. 2009, no. 2009, pp.1-6.
https://search.emarefa.net/detail/BIM-451925
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-451925
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر