Clinical Evaluation of a Mobile Heart Rhythm Telemonitoring System
المؤلفون المشاركون
Dimitrov, Nikolay
Simova, Iana
Mateev, Hristo
Katova, Tzvetana
المصدر
العدد
المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2012-10-14
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Purpose.
To evaluate the clinical applicability of a telemonitoring system: telemetric system for collection and distant surveillance of medical information (TEMEO).
Methods.
We evaluated 60 patients, applying simultaneously standard Holter ECG and telemonitoring.
Two different comparisons were performed: (1) TEMEO ECG with standard 12-lead ECG; (2) TEMEO Holter with standard ECG Holter.
Results.
We found a very high coincidence rate (99.3%) between TEMEO derived ECGs and standard ECGs.
Intraclass correlation coefficient analysis revealed high and significant correlation coefficients regarding average, maximal, and minimal heart rate, % of time in tachycardia, single supraventricular ectopic beats (SVEB), and single and couplets of ventricular ectopic beats (VEB) between Holter ECG and TEMEO derived parameters.
Couplets of SVEB were recorded as different by the two monitoring systems, however, with a borderline statistical significance.
Conclusions.
TEMEO derived ECGs have a very high coincidence rate with standard ECGs.
TEMEO patient monitoring provides results that are similar to those derived from a standard Holter ECG.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Mateev, Hristo& Simova, Iana& Katova, Tzvetana& Dimitrov, Nikolay. 2012. Clinical Evaluation of a Mobile Heart Rhythm Telemonitoring System. ISRN Cardiology،Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-453338
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Mateev, Hristo…[et al.]. Clinical Evaluation of a Mobile Heart Rhythm Telemonitoring System. ISRN Cardiology No. 2012 (2012), pp.1-8.
https://search.emarefa.net/detail/BIM-453338
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Mateev, Hristo& Simova, Iana& Katova, Tzvetana& Dimitrov, Nikolay. Clinical Evaluation of a Mobile Heart Rhythm Telemonitoring System. ISRN Cardiology. 2012. Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-453338
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-453338
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر