Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System

المؤلفون المشاركون

Blázquez, J.
Bécares, V.

المصدر

Science and Technology of Nuclear Installations

العدد

المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2012-04-29

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

العلوم الهندسية و تكنولوجيا المعلومات

الملخص EN

The operation of accelerator-driven systems or spallation sources requires the monitoring of intense neutron fluxes, which may be billions-fold more intense than the fluxes obtained with usual radioactive sources.

If a neutron detector is placed near a very intense source, it can become saturated because of detector dead time.

On the contrary, if it is placed far away from the source, it will lose counting statistics.

For this reason, there must exist an optimal position for placing the detector.

The optimal position is defined as the one with the minimal relative uncertainty in the counting rate.

In this work, we review the techniques to determine the detector dead time that can be applied with an accelerator-driven subcritical system or a spallation source.

For the case of a spallation source, counting rates do not follow Poisson's statistics because of the multiplicity of the number of neutrons emitted by incident proton.

It has been found a simple expression that relates the optimal counting rate with the source multiplicity and the uncertainty in the determination of the dead time.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Bécares, V.& Blázquez, J.. 2012. Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System. Science and Technology of Nuclear Installations،Vol. 2012, no. 2012, pp.1-7.
https://search.emarefa.net/detail/BIM-456568

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Bécares, V.& Blázquez, J.. Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System. Science and Technology of Nuclear Installations No. 2012 (2012), pp.1-7.
https://search.emarefa.net/detail/BIM-456568

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Bécares, V.& Blázquez, J.. Detector Dead Time Determination and Optimal Counting Rate for a Detector Near a Spallation Source or a Subcritical Multiplying System. Science and Technology of Nuclear Installations. 2012. Vol. 2012, no. 2012, pp.1-7.
https://search.emarefa.net/detail/BIM-456568

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-456568