الملخص EN

Most of the failures of induction motors become insulation faults, causing a permanent damage.

Using differential current transformers, a system capable of insulation fault detection was developed, based on the differential relay protection scheme.

Both signal injection and fault detection circuitry were integrated in a single chip.

The proposed scheme is faster than other existing protection and not restricted to protect induction motors, but several other devices (such as IGBTs) and systems.

This paper explains the principle of operation of fault protection scheme and analyzes an integrated implementation through simulations and experimental results.

A power-integrated circuit (PIC) implementation is presented.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Bulacio, M. F.& González, T. A.& Marinelli, G.& Alonso, R.& Tacca, Hernán. 2012. Power-Integrated Circuit Active Leakage Current Detector. Advances in Power Electronics،Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-459132

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Bulacio, M. F.…[et al.]. Power-Integrated Circuit Active Leakage Current Detector. Advances in Power Electronics No. 2012 (2012), pp.1-8.
https://search.emarefa.net/detail/BIM-459132

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Bulacio, M. F.& González, T. A.& Marinelli, G.& Alonso, R.& Tacca, Hernán. Power-Integrated Circuit Active Leakage Current Detector. Advances in Power Electronics. 2012. Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-459132

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-459132