Micropower Impulse Radar : A Novel Technology for Rapid, Real-Time Detection of Pneumothorax

المؤلفون المشاركون

Greszler, Alan
Levy, Phillip D.
Wielinski, Tracey

المصدر

Emergency Medicine International

العدد

المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2011-05-30

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Pneumothorax detection in emergency situations must be rapid and at the point of care.

Current standards for detection of a pneumothorax are supine chest X-rays, ultrasound, and CT scans.

Unfortunately these tools and the personnel necessary for their facile utilization may not be readily available in acute circumstances, particularly those which occur in the pre-hospital setting.

The decision to treat therefore, is often made without adequate information.

In this report, we describe a novel hand-held device that utilizes Micropower Impulse Radar to reliably detect the presence of a pneumothorax.

The technology employs ultra wide band pulses over a frequency range of 500 MHz to 6 GHz and a proprietary algorithm analyzes return echoes to determine if a pneumothorax is present with no user interpretation required.

The device has been evaluated in both trauma and surgical environments with sensitivity of 93% and specificity of 85%.

It is has the CE Mark and is available for sale in Europe.

Post market studies are planned starting in May of 2011.

Clinical studies to support the FDA submission will be completed in the first quarter of 2012.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Levy, Phillip D.& Wielinski, Tracey& Greszler, Alan. 2011. Micropower Impulse Radar : A Novel Technology for Rapid, Real-Time Detection of Pneumothorax. Emergency Medicine International،Vol. 2011, no. 2011, pp.1-5.
https://search.emarefa.net/detail/BIM-459835

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Levy, Phillip D.…[et al.]. Micropower Impulse Radar : A Novel Technology for Rapid, Real-Time Detection of Pneumothorax. Emergency Medicine International No. 2011 (2011), pp.1-5.
https://search.emarefa.net/detail/BIM-459835

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Levy, Phillip D.& Wielinski, Tracey& Greszler, Alan. Micropower Impulse Radar : A Novel Technology for Rapid, Real-Time Detection of Pneumothorax. Emergency Medicine International. 2011. Vol. 2011, no. 2011, pp.1-5.
https://search.emarefa.net/detail/BIM-459835

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-459835