![](/images/graphics-bg.png)
Endoscopic Ultrasound-Guided Celiac Plexus Neurolysis in Pancreatic Cancer : A Prospective Pilot Study of Safety Using 10 mL versus 20 mL Alcohol
المؤلفون المشاركون
Juan, Michelle
McHenry, Lee
Johnson, Cynthia
Kroenke, Kurt
DeWitt, John M.
Rawl, Susan M.
al-Haddad, Mohammad
Sherman, Stuart
McGreevy, Kathy
LeBlanc, Julia K.
المصدر
Diagnostic and Therapeutic Endoscopy
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-01-08
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
Background.
The dose of alcohol used in EUS-CPN is not standardized.
The objective was to compare the safety of 20 mL alcohol versus 10 mL alcohol during EUS-CPN for patients with pancreatic cancer-related pain.
Methods.
20 patients were selected to receive 10 mL or 20 mL of alcohol during EUS-CPN.
Followup was done at baseline, 24 hours, and weekly.
Health-related quality of life (HRQoL) was assessed at baseline, week 2, week 4, and every 4 weeks thereafter until pain returned.
Results.
There were no major complications in both groups.
Minor self-limited adverse effects were seen in 6 (30%) subjects and included lightheadedness in 1 (5%), transient diarrhea in 2 (10%), and transient nausea and vomiting in 3.
Pain relief was similar in both groups: 80% in the 10 mL group and 100% in the 20 mL group (P=0.21).
The mean (± SD) duration of pain relief in the 10 mL and 20 mL groups was 7.9±10.8 and 8.4±9.2 weeks, respectively.
30% of patients in each group had complete pain relief.
Conclusions.
EUS-CPN using 20 mL of alcohol is safe.
Similar clinical outcomes were seen in both groups.
Further investigations to confirm these findings are warranted.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
LeBlanc, Julia K.& Rawl, Susan M.& Juan, Michelle& Johnson, Cynthia& Kroenke, Kurt& McHenry, Lee…[et al.]. 2013. Endoscopic Ultrasound-Guided Celiac Plexus Neurolysis in Pancreatic Cancer : A Prospective Pilot Study of Safety Using 10 mL versus 20 mL Alcohol. Diagnostic and Therapeutic Endoscopy،Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-463784
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
LeBlanc, Julia K.…[et al.]. Endoscopic Ultrasound-Guided Celiac Plexus Neurolysis in Pancreatic Cancer : A Prospective Pilot Study of Safety Using 10 mL versus 20 mL Alcohol. Diagnostic and Therapeutic Endoscopy No. 2013 (2013), pp.1-6.
https://search.emarefa.net/detail/BIM-463784
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
LeBlanc, Julia K.& Rawl, Susan M.& Juan, Michelle& Johnson, Cynthia& Kroenke, Kurt& McHenry, Lee…[et al.]. Endoscopic Ultrasound-Guided Celiac Plexus Neurolysis in Pancreatic Cancer : A Prospective Pilot Study of Safety Using 10 mL versus 20 mL Alcohol. Diagnostic and Therapeutic Endoscopy. 2013. Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-463784
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-463784
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)