Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique
المؤلفون المشاركون
Franco, Eduardo Batista
Herrera, Francyle Simões
Benetti, Ana Raquel
Cunha, Leonardo Fernandes da
المصدر
العدد
المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2011-07-25
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
Objective.
To investigate the accuracy of dies obtained from single-step and 2-step double-mix impressions.
Material and Methods.
Impressions (n=10) of a stainless steel die simulating a complete crown preparation were performed using a polyether (Impregum Soft Heavy and Light body) and a vinyl polysiloxane (Perfectim Blue Velvet and Flexi-Velvet) in two consistencies, in one or two (without relief) steps.
Accuracy of the stone dies was accessed at a measuring microscope, using a metallic crown with perfect fit to the reference crown preparation.
Data were submitted to 2-way ANOVA and Tukey test (α=0.05).
Results.
The single-step technique resulted in slightly larger dies, while the 2-step technique without relief produced significantly smaller dies, when compared to the original stainless steel die.
Stone dies obtained from 2-step polyether impressions were significantly smaller when compared to dies obtained from 2-step vinyl polysiloxane impressions (Impregum 2-step: −290.94 ± 71.64 μm; Perfectim 2-step: −201.86 ± 28.58 μm).
No significant differences were observed in dies obtained from either polyether or vinyl polysiloxane with the single-step technique (Impregum single-step: 63.52 ± 16.60 μm; Perfectim single-step: 79.40 ± 14.11 μm).
Conclusion.
Higher discrepancies were detected for the 2-step impression technique without relief for the investigated materials.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Franco, Eduardo Batista& Cunha, Leonardo Fernandes da& Herrera, Francyle Simões& Benetti, Ana Raquel. 2011. Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique. ISRN Dentistry،Vol. 2011, no. 2011, pp.1-5.
https://search.emarefa.net/detail/BIM-464240
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Franco, Eduardo Batista…[et al.]. Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique. ISRN Dentistry No. 2011 (2011), pp.1-5.
https://search.emarefa.net/detail/BIM-464240
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Franco, Eduardo Batista& Cunha, Leonardo Fernandes da& Herrera, Francyle Simões& Benetti, Ana Raquel. Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique. ISRN Dentistry. 2011. Vol. 2011, no. 2011, pp.1-5.
https://search.emarefa.net/detail/BIM-464240
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-464240
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر