Contribution of a Real Depth Distance Stereoacuity Test to Clinical Management
المؤلفون المشاركون
Wylie, J. M.
Sueke, H.
Young, B. J.
Kaye, Stephen
المصدر
العدد
المجلد 2009، العدد 2009 (31 ديسمبر/كانون الأول 2009)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2009-07-05
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
Measurement of Stereopsis forms an important part of the clinical assessment of patients with disorders of ocular motility.
The introduction of a real depth distance stereoacuity test (FD2) was evaluated in clinical practice and to what extent the introduction affected clinical management.
Seventy-three patients under evaluation before and following the introduction of the test were included.
Combined thresholds were measured at near using the Frisby and TNO test and at distance using the FD2.
Fifty healthy controls were included.
Forty-five patients demonstrated Stereopsis using the FD2 and 23 of these had a change in their management based in part on their responses using the FD2.
Patients with evidence of Stereopsis using the FD2 were significantly more likely to have change in their management than expected from the whole sample (P=.02).
The introduction of a real depth distance stereoacuity test into clinical practice contributed to a change in management when used in conjunction with other tests.
The usefulness of the FD2 is limited by its range at 6 m.
Use at closer distances necessitates the calculation of binocular threshold from the combined and monocular threshold.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Young, B. J.& Sueke, H.& Wylie, J. M.& Kaye, Stephen. 2009. Contribution of a Real Depth Distance Stereoacuity Test to Clinical Management. Journal of Ophthalmology،Vol. 2009, no. 2009, pp.1-6.
https://search.emarefa.net/detail/BIM-464428
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Young, B. J.…[et al.]. Contribution of a Real Depth Distance Stereoacuity Test to Clinical Management. Journal of Ophthalmology No. 2009 (2009), pp.1-6.
https://search.emarefa.net/detail/BIM-464428
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Young, B. J.& Sueke, H.& Wylie, J. M.& Kaye, Stephen. Contribution of a Real Depth Distance Stereoacuity Test to Clinical Management. Journal of Ophthalmology. 2009. Vol. 2009, no. 2009, pp.1-6.
https://search.emarefa.net/detail/BIM-464428
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-464428
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر