In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B

المؤلفون المشاركون

Badran, Bassam
Bou Nasser Eddine, Farah
Tehini, Georges
Berberi, Antoine
Rifai, Khaldoun
Akl, Haidar
El Zein, Nabil

المصدر

International Journal of Dentistry

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-05-11

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

طب الأسنان

الملخص EN

Objectives.

Hollow space between implant and abutment may act as reservoir for commensal and/or pathogenic bacteria representing a potential source of tissue inflammation.

Microbial colonization of the interfacial gap may ultimately lead to infection and bone resorption.

Using Rhodamine B, a sensitive fluorescent tracer dye, we aim in this study to investigate leakage at implant-abutment connection of three implant systems having the same prosthetic interface.

Materials and Methods.

Twenty-one implants (seven Astra Tech, seven Euroteknika, and seven Dentium) with the same prosthetic interface were connected to their original abutments, according to the manufacturers’ recommendation.

After determination of the inner volume of each implant systems, the kinetic quantification of leakage was evaluated for each group using Rhodamine B (10−2 M).

For each group, spectrophotometric analysis was performed to detect leakage with a fluorescence spectrophotometer at 1 h (T0) and 48 h (T1) of incubation time at room temperature.

Results.

Astra Tech had the highest inner volume (6.8 μL), compared to Dentium (4 μL) and Euroteknika (2.9 μL).

At T0 and T1, respectively, the leakage volume and percentage of each system were as follows: Astra Tech 0.043 μL or 1.48% (SD 0.0022), 0.08 μL or 5.56% (SD 0.0074), Euroteknika 0.09 μL or 6.93% (SD 0.0913), 0.21 μL or 20.55% (SD 0.0035), and Dentium 0.07 μL or 4.6% (SD 0.0029), 0.12 μL or 10.47% (SD 0.0072).

Conclusion.

The tested internal conical implant-abutment connections appear to be unable to prevent leakage.

In average, Astra Tech implants showed the highest inner volume and the least leakage.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Berberi, Antoine& Tehini, Georges& Rifai, Khaldoun& Bou Nasser Eddine, Farah& El Zein, Nabil& Badran, Bassam…[et al.]. 2014. In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B. International Journal of Dentistry،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-464999

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Berberi, Antoine…[et al.]. In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B. International Journal of Dentistry No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-464999

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Berberi, Antoine& Tehini, Georges& Rifai, Khaldoun& Bou Nasser Eddine, Farah& El Zein, Nabil& Badran, Bassam…[et al.]. In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B. International Journal of Dentistry. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-464999

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-464999