Biomechanical Assessment of a Patient-Specific Knee Implant Design Using Finite Element Method
المؤلفون المشاركون
Lin, Jianhao
Bai, Jianfeng
Rong, Qiguo
Huang, Yongling
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-06-30
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
Rheumatoid arthritis is the leading cause of disability in young adults.
Total knee arthroplasty has been successfully used to restore the joint function.
Due to small bone size, osteoporosis, and severe soft tissue disease, standard knee implant sometimes cannot be directly applied clinically and patient-specific designs may be a more rational choice.
The purpose of this study was to evaluate the biomechanical behavior of a patient-specific knee implant.
A three-dimensional finite element of total knee arthroplasty was developed.
The mechanical strength and the wear damage of the articular surfaces were analyzed.
The results show that there exist high risks of component fracture and wear damage; the proposed implant design should be abandoned.
The presurgery analysis is helpful in avoiding the potential failure.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Rong, Qiguo& Bai, Jianfeng& Huang, Yongling& Lin, Jianhao. 2014. Biomechanical Assessment of a Patient-Specific Knee Implant Design Using Finite Element Method. BioMed Research International،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-465238
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Rong, Qiguo…[et al.]. Biomechanical Assessment of a Patient-Specific Knee Implant Design Using Finite Element Method. BioMed Research International No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-465238
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Rong, Qiguo& Bai, Jianfeng& Huang, Yongling& Lin, Jianhao. Biomechanical Assessment of a Patient-Specific Knee Implant Design Using Finite Element Method. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-465238
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-465238
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر