Optimal Sensor Placement for Stay Cable Damage Identification of Cable-Stayed Bridge under Uncertainty

المؤلفون المشاركون

Han, Rui-Cong
Hou, Li-Qun
Zhao, Xue-Feng

المصدر

International Journal of Distributed Sensor Networks

العدد

المجلد 2013، العدد - (31 ديسمبر/كانون الأول 2013)، ص ص. 1-18، 18ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-12-19

دولة النشر

مصر

عدد الصفحات

18

التخصصات الرئيسية

هندسة الاتصالات
تكنولوجيا المعلومات وعلم الحاسوب

الملخص EN

Large cable-stayed bridges utilize hundreds of stay cables.

Thus, placing a sensor on every stay cable of bridges for stay cable damage identification (SCDI) is costly and, in most cases, not necessary.

Optimal sensor placement is a significant and critical issue for SCDI.

This paper proposes the criteria for sensor quantity and location optimization for SCDI on the basis of the concept of damage identification reliability index (DIRI) under uncertainty.

Random elimination (RE) algorithm and heuristic random elimination (HRE) algorithm are proposed to solve the sensor quantity optimization calculation problem.

Multistage global optimization (MGO) algorithm is also proposed to solve the sensor location optimization calculation problem.

A case study is conducted to evaluate and verify the criteria and algorithms.

Results indicate that the HRE algorithm can provide better solution with less elapsed time than the RE algorithm can in some cases, and the MGO algorithm can meet the multistage criterion for sensor location optimization and give a satisfying optimized solution.

Theoretical analysis and case study results confirm that the criteria are reasonable and suitable for optimal sensor placement for SCDI.

The proposed algorithms are effective and efficient for practical optimization calculation.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Hou, Li-Qun& Zhao, Xue-Feng& Han, Rui-Cong. 2013. Optimal Sensor Placement for Stay Cable Damage Identification of Cable-Stayed Bridge under Uncertainty. International Journal of Distributed Sensor Networks،Vol. 2013, no. -, pp.1-18.
https://search.emarefa.net/detail/BIM-465911

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Hou, Li-Qun…[et al.]. Optimal Sensor Placement for Stay Cable Damage Identification of Cable-Stayed Bridge under Uncertainty. International Journal of Distributed Sensor Networks Vol. 2013, pp.1-18.
https://search.emarefa.net/detail/BIM-465911

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Hou, Li-Qun& Zhao, Xue-Feng& Han, Rui-Cong. Optimal Sensor Placement for Stay Cable Damage Identification of Cable-Stayed Bridge under Uncertainty. International Journal of Distributed Sensor Networks. 2013. Vol. 2013, no. -, pp.1-18.
https://search.emarefa.net/detail/BIM-465911

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-465911