The HYP-RT Hypoxic Tumour Radiotherapy Algorithm and Accelerated Repopulation Dose per Fraction Study

المؤلفون المشاركون

Bezak, Eva
Yeoh, E.
Harriss-Phillips, Wendy M.

المصدر

Computational and Mathematical Methods in Medicine

العدد

المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-13، 13ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2012-06-19

دولة النشر

مصر

عدد الصفحات

13

التخصصات الرئيسية

الطب البشري

الملخص EN

The HYP-RT model simulates hypoxic tumour growth for head and neck cancer as well as radiotherapy and the effects of accelerated repopulation and reoxygenation.

This report outlines algorithm design, parameterisation and the impact of accelerated repopulation on the increase in dose/fraction needed to control the extra cell propagation during accelerated repopulation.

Cell kill probabilities are based on Linear Quadratic theory, with oxygenation levels and proliferative capacity influencing cell death.

Hypoxia is modelled through oxygen level allocation based on pO2 histograms.

Accelerated repopulation is modelled by increasing the stem cell symmetrical division probability, while the process of reoxygenation utilises randomised pO2 increments to the cell population after each treatment fraction.

Propagation of 108 tumour cells requires 5–30 minutes.

Controlling the extra cell growth induced by accelerated repopulation requires a dose/fraction increase of 0.5–1.0 Gy, in agreement with published reports.

The average reoxygenation pO2 increment of 3 mmHg per fraction results in full tumour reoxygenation after shrinkage to approximately 1 mm.

HYP-RT is a computationally efficient model simulating tumour growth and radiotherapy, incorporating accelerated repopulation and reoxygenation.

It may be used to explore cell kill outcomes during radiotherapy while varying key radiobiological and tumour specific parameters, such as the degree of hypoxia.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Harriss-Phillips, Wendy M.& Bezak, Eva& Yeoh, E.. 2012. The HYP-RT Hypoxic Tumour Radiotherapy Algorithm and Accelerated Repopulation Dose per Fraction Study. Computational and Mathematical Methods in Medicine،Vol. 2012, no. 2012, pp.1-13.
https://search.emarefa.net/detail/BIM-466072

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Harriss-Phillips, Wendy M.…[et al.]. The HYP-RT Hypoxic Tumour Radiotherapy Algorithm and Accelerated Repopulation Dose per Fraction Study. Computational and Mathematical Methods in Medicine No. 2012 (2012), pp.1-13.
https://search.emarefa.net/detail/BIM-466072

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Harriss-Phillips, Wendy M.& Bezak, Eva& Yeoh, E.. The HYP-RT Hypoxic Tumour Radiotherapy Algorithm and Accelerated Repopulation Dose per Fraction Study. Computational and Mathematical Methods in Medicine. 2012. Vol. 2012, no. 2012, pp.1-13.
https://search.emarefa.net/detail/BIM-466072

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-466072