![](/images/graphics-bg.png)
Using Surgical Microscope for Sclera Buckling and Transscleral Cryopexy : An Alternative Procedure of Treatment for Rhegmatogenous Retinal Detachment
المؤلفون المشاركون
Zhong, Liu-xue-ying
Du, Yi
Zhang, Shao-chong
Liu, Wen
Huang, Su-Ying
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-03-26
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
Purpose.
To observe the long-term effectiveness of scleral buckling and transscleral cryopexy conducted under a surgical microscope in the treatment of uncomplicated rhegmatogenous retinal detachment.
Methods.
This was a retrospective analysis in a total of 227 consecutive patients (244 eyes) with uncomplicated rhegmatogenous retinal detachment (proliferative vitreoretinopathy ≤ C2).
All patients underwent scleral buckling and transscleral cryopexy under a surgical microscope without using a binocular indirect ophthalmoscope or a contact lens.
Results.
After initial surgery, complete retinal reattachment was achieved in 226 eyes (92.6%), and retinal redetachment developed in 18 eyes (7.4%).
The causes of retinal redetachment included presence of new breaks in eight eyes (44%), failure to completely seal the breaks in five eyes (28%), missed retinal breaks in four eyes (22%), and iatrogenic retinal breaks in one eye (6%).
Scleral buckling surgery was performed again in 12 eyes (66%).
Four eyes (22%) developed proliferative vitreoretinopathy and then were treated by vitrectomy.
The sealing of retinal breaks and complete retinal reattachment were achieved in 241 eyes (98.8%).
Conclusion.
Probably because of clear visualization of retinal breaks and being controllable under a surgical microscope, the microsurgery of scleral buckling and transscleral cryopexy for uncomplicated retinal detachment exhibits advisable effectiveness.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Zhong, Liu-xue-ying& Du, Yi& Liu, Wen& Huang, Su-Ying& Zhang, Shao-chong. 2014. Using Surgical Microscope for Sclera Buckling and Transscleral Cryopexy : An Alternative Procedure of Treatment for Rhegmatogenous Retinal Detachment. BioMed Research International،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-466201
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Zhong, Liu-xue-ying…[et al.]. Using Surgical Microscope for Sclera Buckling and Transscleral Cryopexy : An Alternative Procedure of Treatment for Rhegmatogenous Retinal Detachment. BioMed Research International No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-466201
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Zhong, Liu-xue-ying& Du, Yi& Liu, Wen& Huang, Su-Ying& Zhang, Shao-chong. Using Surgical Microscope for Sclera Buckling and Transscleral Cryopexy : An Alternative Procedure of Treatment for Rhegmatogenous Retinal Detachment. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-466201
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-466201
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)