Noninvasive Measurement of Conductivity Anisotropy at Larmor Frequency Using MRI

المؤلفون المشاركون

Kim, Dong-Hyun
Seo, Jin Keun
Lee, Joonsung
Song, Yizhuang
Choi, Narae
Cho, Sungmin

المصدر

Computational and Mathematical Methods in Medicine

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-12، 12ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-03-11

دولة النشر

مصر

عدد الصفحات

12

التخصصات الرئيسية

الطب البشري

الملخص EN

Anisotropic electrical properties can be found in biological tissues such as muscles and nerves.

Conductivity tensor is a simplified model to express the effective electrical anisotropic information and depends on the imaging resolution.

The determination of the conductivity tensor should be based on Ohm's law.

In other words, the measurement of partial information of current density and the electric fields should be made.

Since the direct measurements of the electric field and the current density are difficult, we use MRI to measure their partial information such as B1 map; it measures circulating current density and circulating electric field.

In this work, the ratio of the two circulating fields, termed circulating admittivity, is proposed as measures of the conductivity anisotropy at Larmor frequency.

Given eigenvectors of the conductivity tensor, quantitative measurement of the eigenvalues can be achieved from circulating admittivity for special tissue models.

Without eigenvectors, qualitative information of anisotropy still can be acquired from circulating admittivity.

The limitation of the circulating admittivity is that at least two components of the magnetic fields should be measured to capture anisotropic information.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Lee, Joonsung& Song, Yizhuang& Choi, Narae& Cho, Sungmin& Seo, Jin Keun& Kim, Dong-Hyun. 2013. Noninvasive Measurement of Conductivity Anisotropy at Larmor Frequency Using MRI. Computational and Mathematical Methods in Medicine،Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-470941

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Lee, Joonsung…[et al.]. Noninvasive Measurement of Conductivity Anisotropy at Larmor Frequency Using MRI. Computational and Mathematical Methods in Medicine No. 2013 (2013), pp.1-12.
https://search.emarefa.net/detail/BIM-470941

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Lee, Joonsung& Song, Yizhuang& Choi, Narae& Cho, Sungmin& Seo, Jin Keun& Kim, Dong-Hyun. Noninvasive Measurement of Conductivity Anisotropy at Larmor Frequency Using MRI. Computational and Mathematical Methods in Medicine. 2013. Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-470941

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-470941