Primary Stability of Self-Drilling and Self-Tapping Mini-Implant in Tibia of Diabetes-Induced Rabbits
المؤلفون المشاركون
Jeong, Do-Min
Kook, Yoon-Ah
Cho, Il-Sik
Paek, Janghyun
Kim, Eun-Young
Nelson, Gerald
Park, Jea-Beom
المصدر
International Journal of Dentistry
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-05-11
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Objective.
This study aimed to evaluate effects of type 1 diabetes mellitus and mini-implant placement method on the primary stability of mini-implants by comparing mechanical stability and microstructural/histological differences.
Methods.
After 4 weeks of diabetic induction, 48 mini-implants (24 self-tapping and 24 self-drilling implants) were placed on the tibia of 6 diabetic and 6 normal rabbits.
After 4 weeks, the rabbits were sacrificed.
Insertion torque, removal torque, insertion energy, and removal energy were measured with a surgical engine on 8 rabbits.
Remaining 4 rabbits were analyzed by microcomputed tomography (micro-CT) and bone histomorphometry.
Results.
Total insertion energy was higher in self-drilling groups than self-tapping groups in both control and diabetic groups.
Diabetic groups had more trabecular separation in bone marrow than the control groups in both SD and ST groups.
Micro-CT analysis showed deterioration of bone quality in tibia especially in bone marrow of diabetic rabbits.
However, there was no statistically significant correlation between self-drilling and self-tapping group for the remaining measurements in both control and diabetic groups.
Conclusions.
Type 1 diabetes mellitus and placement method of mini-implant did not affect primary stability of mini-implants.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Park, Jea-Beom& Kim, Eun-Young& Paek, Janghyun& Kook, Yoon-Ah& Jeong, Do-Min& Cho, Il-Sik…[et al.]. 2014. Primary Stability of Self-Drilling and Self-Tapping Mini-Implant in Tibia of Diabetes-Induced Rabbits. International Journal of Dentistry،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-471575
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Park, Jea-Beom…[et al.]. Primary Stability of Self-Drilling and Self-Tapping Mini-Implant in Tibia of Diabetes-Induced Rabbits. International Journal of Dentistry No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-471575
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Park, Jea-Beom& Kim, Eun-Young& Paek, Janghyun& Kook, Yoon-Ah& Jeong, Do-Min& Cho, Il-Sik…[et al.]. Primary Stability of Self-Drilling and Self-Tapping Mini-Implant in Tibia of Diabetes-Induced Rabbits. International Journal of Dentistry. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-471575
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-471575
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)