Purpose.
To compare anterior chamber depth (ACD), representing the distance between the anterior corneal surface and anterior lens surface measurements between the Galilei Dual Scheimpflug Analyzer and the IOLMaster.
Methods.
A retrospective review of 65 individual patient eyes with normal anterior segments, and no prior ocular surgery was performed.
Patients underwent ACD measurements with both devices during the same session by a trained examiner.
Interdevice agreement was evaluated using paired two-tailed t-tests, Pearson correlation coefficient, and Bland-Altman analysis.
Results.
The mean ± standard deviation (SD) ACD for the Galilei and IOLMaster was 3.37 ± 0.36 mm (range from 2.62 to 4.13) and 3.25 ± 0.38 mm (range from 2.34 to 3.92), respectively (Pearson correlation coefficient = 0.96).
ACD mean difference was 0.12 mm (P < 0.0001); 95% limits of agreement was from −0.09 to 0.34.
The Galilei measured slightly longer ACD values than the IOLMaster.
There was no relationship between axial length and interdevice difference.
Conclusion.
ACD measurements correlate well between the Galilei and IOLMaster, with Galilei values on average 0.12 mm longer than the IOLMaster.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Patel, Roma P.& Pandit, Rahul T.. 2012. Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster. Journal of Ophthalmology،Vol. 2012, no. 2012, pp.1-4.
https://search.emarefa.net/detail/BIM-471648
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Patel, Roma P.& Pandit, Rahul T.. Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster. Journal of Ophthalmology No. 2012 (2012), pp.1-4.
https://search.emarefa.net/detail/BIM-471648
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Patel, Roma P.& Pandit, Rahul T.. Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster. Journal of Ophthalmology. 2012. Vol. 2012, no. 2012, pp.1-4.
https://search.emarefa.net/detail/BIM-471648
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-471648
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر