Region-Based Partial Volume Correction Techniques for PET Imaging : Sinogram Implementation and Robustness

المؤلفون المشاركون

Kusano, Maggie
Caldwell, Curtis B.
Poon, Ian
Armstrong, Jennifer
Sattarivand, Mike
Szilagyi, Gregory M.

المصدر

International Journal of Molecular Imaging

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-12، 12ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-12-17

دولة النشر

مصر

عدد الصفحات

12

التخصصات الرئيسية

الطب البشري

الملخص EN

Background/Purpose.

Limited spatial resolution of positron emission tomography (PET) requires partial volume correction (PVC).

Region-based PVC methods are based on geometric transfer matrix implemented either in image-space (GTM) or sinogram-space (GTMo), both with similar performance.

Although GTMo is slower, it more closely simulates the 3D PET image acquisition, accounts for local variations of point spread function, and can be implemented for iterative reconstructions.

A recent image-based symmetric GTM (sGTM) has shown improvement in noise characteristics and robustness to misregistration over GTM.

This study implements the sGTM method in sinogram space (sGTMo), validates it, and evaluates its performance.

Methods.

Two 3D sphere and brain digital phantoms and a physical sphere phantom were used.

All four region-based PVC methods (GTM, GTMo, sGTM, and sGTMo) were implemented and their performance was evaluated.

Results.

All four PVC methods had similar accuracies.

Both noise propagation and robustness of the sGTMo method were similar to those of sGTM method while they were better than those of GTMo method especially for smaller objects.

Conclusion.

The sGTMo was implemented and validated.

The performance of the sGTMo in terms of noise characteristics and robustness to misregistration is similar to that of the sGTM method and improved compared to the GTMo method.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Sattarivand, Mike& Armstrong, Jennifer& Szilagyi, Gregory M.& Kusano, Maggie& Poon, Ian& Caldwell, Curtis B.. 2013. Region-Based Partial Volume Correction Techniques for PET Imaging : Sinogram Implementation and Robustness. International Journal of Molecular Imaging،Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-472080

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Kusano, Maggie…[et al.]. Region-Based Partial Volume Correction Techniques for PET Imaging : Sinogram Implementation and Robustness. International Journal of Molecular Imaging No. 2013 (2013), pp.1-12.
https://search.emarefa.net/detail/BIM-472080

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Sattarivand, Mike& Armstrong, Jennifer& Szilagyi, Gregory M.& Kusano, Maggie& Poon, Ian& Caldwell, Curtis B.. Region-Based Partial Volume Correction Techniques for PET Imaging : Sinogram Implementation and Robustness. International Journal of Molecular Imaging. 2013. Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-472080

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-472080