الملخص EN
In this study, a sensitive, simple, and reliable HPLC method for quantification of pregabalin in human plasma was developed and validated.
1-Fluoro-2,4-dinitrobenzene was used as precolumn derivatization agent.
For chromatography, an analytical reversed phase (C18) column and a mixture of Na2HPO4 10 mM (pH 8.0)—methanol (35 : 65 v/v) were used as stationary and mobile phase, respectively.
Detection was performed using a UV detector tuned at 360 nm.
The linearity of the method was tested over the concentration range 1–4500 ng/mL in 500 μL of human plasma and satisfactory results were obtained (r2 > 0.999).
The method showed good precision and accuracy in terms of within—between days relative standard deviations and percent deviation from nominated values (in the range of 4.3–12.7% and 2.6–8.0%, resp.).
The limit of quantification of the method was found to be 1 ng/mL which is better than previously reported method and indicates its potential application for sensitive bioanalysis.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ahmadkhaniha, Reza& Mottaghi, Siavash& Zargarpoor, Mohammad& Souri, Effat. 2014. Validated HPLC Method for Quantification of Pregabalin in Human Plasma Using 1-Fluoro-2,4-dinitrobenzene as Derivatization Agent. Chromatography Research International،Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-472541
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ahmadkhaniha, Reza…[et al.]. Validated HPLC Method for Quantification of Pregabalin in Human Plasma Using 1-Fluoro-2,4-dinitrobenzene as Derivatization Agent. Chromatography Research International No. 2014 (2014), pp.1-6.
https://search.emarefa.net/detail/BIM-472541
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ahmadkhaniha, Reza& Mottaghi, Siavash& Zargarpoor, Mohammad& Souri, Effat. Validated HPLC Method for Quantification of Pregabalin in Human Plasma Using 1-Fluoro-2,4-dinitrobenzene as Derivatization Agent. Chromatography Research International. 2014. Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-472541
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-472541
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر