![](/images/graphics-bg.png)
A Multiplex Snapback Primer System for the Enrichment and Detection of JAK2 V617F and MPL W515LK Mutations in Philadelphia-Negative Myeloproliferative Neoplasms
المؤلفون المشاركون
Su, Bing
Li, Shibao
Zhang, Xinju
Guan, Ming
Zhang, Chen
Kang, Zhihua
Xu, Xiao
Zhang, Yunqing
Wu, Zhiyuan
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-11، 11ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-03-04
دولة النشر
مصر
عدد الصفحات
11
التخصصات الرئيسية
الملخص EN
A multiplex snapback primer system was developed for the simultaneous detection of JAK2 V617F and MPL W515L/K mutations in Philadelphia chromosome- (Ph-) negative myeloproliferative neoplasms (MPNs).
The multiplex system comprises two snapback versus limiting primer sets for JAK2 and MPL mutation enrichment and detection, respectively.
Linear-After exponential (LATE) PCR strategy was employed for the primer design to maximize the amplification efficiency of the system.
Low ionic strength buffer and rapid PCR protocol allowed for selective amplification of the mutant alleles.
Amplification products were analyzed by melting curve analysis for mutation identification.
The multiplex system archived 0.1% mutation load sensitivity and <5% coefficient of variation inter-/intra-assay reproducibility.
120 clinical samples were tested by the multiplex snapback primer assay, and verified with amplification refractory system (ARMS), quantitative PCR (qPCR) and Sanger sequencing method.
The multiplex system, with a favored versatility, provided the molecular diagnosis of Ph-negative MPNs with a suitable implement and simplified the genetic test process.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Wu, Zhiyuan& Zhang, Yunqing& Zhang, Xinju& Xu, Xiao& Kang, Zhihua& Li, Shibao…[et al.]. 2014. A Multiplex Snapback Primer System for the Enrichment and Detection of JAK2 V617F and MPL W515LK Mutations in Philadelphia-Negative Myeloproliferative Neoplasms. BioMed Research International،Vol. 2014, no. 2014, pp.1-11.
https://search.emarefa.net/detail/BIM-473130
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Wu, Zhiyuan…[et al.]. A Multiplex Snapback Primer System for the Enrichment and Detection of JAK2 V617F and MPL W515LK Mutations in Philadelphia-Negative Myeloproliferative Neoplasms. BioMed Research International No. 2014 (2014), pp.1-11.
https://search.emarefa.net/detail/BIM-473130
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Wu, Zhiyuan& Zhang, Yunqing& Zhang, Xinju& Xu, Xiao& Kang, Zhihua& Li, Shibao…[et al.]. A Multiplex Snapback Primer System for the Enrichment and Detection of JAK2 V617F and MPL W515LK Mutations in Philadelphia-Negative Myeloproliferative Neoplasms. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-11.
https://search.emarefa.net/detail/BIM-473130
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-473130
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)