A Biocompatible Nanocomposite for Glucose Sensing
المؤلفون المشاركون
Norouzi, Parviz
Rahimi, Parvaneh
Ghourchian, Hedayatollah
Ganjali, Mohammad Reza
Rafiee-Pour, Hossain-Ali
المصدر
International Journal of Electrochemistry
العدد
المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2011-04-27
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
A nanocomposite containing amine functionalized multiwalled carbon nanotubes and a room temperature ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) was prepared and applied for glucose oxidase (GOx) immobilization on glassy carbon electrode.
The proposed nanocomposite provided a favorable microenvironment to preserve the bioactivity of GOx.
It could also effectively facilitate the enzyme direct electron transfer to the electrode.
This brought about a remarkable improvement in the sensitivity of the glucose biosensor.
Under the optimum experimental conditions, the formal potential of GOx was about −467.5 mV.
Moreover, the sensitivity and response time of the biosensor toward glucose were 1277 μA mM-1 cm-2 and 6 s, respectively.
The biosensor provided a linear dynamic response between 0.1 and 43 μM with a very low detection limit of 63 nM.
Also, the values for apparent Michaelis-Menten constant and maximum current were obtained as 18 μM and 2.7 μA, respectively.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Rahimi, Parvaneh& Ghourchian, Hedayatollah& Rafiee-Pour, Hossain-Ali& Norouzi, Parviz& Ganjali, Mohammad Reza. 2011. A Biocompatible Nanocomposite for Glucose Sensing. International Journal of Electrochemistry،Vol. 2011, no. 2011, pp.1-7.
https://search.emarefa.net/detail/BIM-474076
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Rahimi, Parvaneh…[et al.]. A Biocompatible Nanocomposite for Glucose Sensing. International Journal of Electrochemistry No. 2011 (2011), pp.1-7.
https://search.emarefa.net/detail/BIM-474076
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Rahimi, Parvaneh& Ghourchian, Hedayatollah& Rafiee-Pour, Hossain-Ali& Norouzi, Parviz& Ganjali, Mohammad Reza. A Biocompatible Nanocomposite for Glucose Sensing. International Journal of Electrochemistry. 2011. Vol. 2011, no. 2011, pp.1-7.
https://search.emarefa.net/detail/BIM-474076
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-474076
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)