![](/images/graphics-bg.png)
Standard Enucleation with Aluminium Oxide Implant (Bioceramic) Covered with Patient's Sclera
المؤلفون المشاركون
Meduri, Alessandro
Lupo, Stefano
Pichi, Francesco
Nucci, Paolo
Cavarretta, Sonia
Lembo, Andrea
Morara, Mariachiara
Zigiotti, Gian Luigi
Ranno, Stefano
Nam, Sang Min
المصدر
العدد
المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2012-04-30
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
العلوم الطبيعية والحياتية (متداخلة التخصصات)
الطب البشري
تكنولوجيا المعلومات وعلم الحاسوب
الملخص EN
Purpose.
We describe in our study a modified standard enucleation, using sclera harvested from the enucleated eye to cover the prosthesis in order to insert a large porous implant and to reduce postoperative complication rates in a phthisis globe.
Methods.
We perform initially a standard enucleation.
The porous implant (Bioceramic) is then covered only partially by the patient's sclera.
The implant is inserted in the posterior Tenon's space with the scleral covering looking at front.
All patients were followed at least for twelve months (average followup 16 months).
Results.
We performed nineteen primary procedures (19 patients, 19 eyes, x M; x F) and secondary, to fill the orbital cavity in patients already operated by standard evisceration (7 patients, 7 eyes).
There were no cases of implant extrusion.
The orbital volume was well reintegrated.
Conclusion.
Our procedure was safe and effective.
All patients had a good cosmetic result after final prosthetic fitting and we also achieved good prothesis mobility.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Zigiotti, Gian Luigi& Cavarretta, Sonia& Morara, Mariachiara& Nam, Sang Min& Ranno, Stefano& Pichi, Francesco…[et al.]. 2012. Standard Enucleation with Aluminium Oxide Implant (Bioceramic) Covered with Patient's Sclera. The Scientific World Journal،Vol. 2012, no. 2012, pp.1-4.
https://search.emarefa.net/detail/BIM-475021
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Zigiotti, Gian Luigi…[et al.]. Standard Enucleation with Aluminium Oxide Implant (Bioceramic) Covered with Patient's Sclera. The Scientific World Journal No. 2012 (2012), pp.1-4.
https://search.emarefa.net/detail/BIM-475021
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Zigiotti, Gian Luigi& Cavarretta, Sonia& Morara, Mariachiara& Nam, Sang Min& Ranno, Stefano& Pichi, Francesco…[et al.]. Standard Enucleation with Aluminium Oxide Implant (Bioceramic) Covered with Patient's Sclera. The Scientific World Journal. 2012. Vol. 2012, no. 2012, pp.1-4.
https://search.emarefa.net/detail/BIM-475021
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-475021
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)