Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients

المؤلفون المشاركون

Figus, Michele
Pablo, Luis E.
Ara, Mirian
Ferrandez, Blanca
Ferreras, Antonio L.
Calvo, Pilar
Otin, Sofia
Frezzotti, Paolo
Abadia, Beatriz

المصدر

BioMed Research International

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-06-16

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

Objective.

To evaluate the relationship between spectral-domain optical coherence tomography (OCT) and standard automated perimetry (SAP) in healthy and glaucoma individuals.

Methods.

The sample comprised 338 individuals divided into 2 groups according to intraocular pressure and visual field outcomes.

All participants underwent a reliable SAP and imaging of the optic nerve head with the Cirrus OCT.

Pearson correlations were calculated between threshold sensitivity values of SAP (converted to linear scale) and OCT parameters.

Results.

Mean age did not differ between the control and glaucoma groups (59.55 ± 9.7 years and 61.05 ± 9.4 years, resp.; P=0.15).

Significant differences were found for the threshold sensitivities at each of the 52 points evaluated with SAP (P<0.001) and the peripapillary retinal nerve fiber layer (RNFL) thicknesses, except at 3 and 9 clock-hour positions between both groups.

Mild to moderate correlations (ranging between 0.286 and 0.593; P<0.001) were observed between SAP and most OCT parameters in the glaucoma group.

The strongest correlations were found between the inferior RNFL thickness and the superior hemifield points.

The healthy group showed lower and weaker correlations than the glaucoma group.

Conclusions.

Peripapillary RNFL thickness measured with Cirrus OCT showed mild to moderate correlations with SAP in glaucoma patients.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Abadia, Beatriz& Ferreras, Antonio L.& Calvo, Pilar& Ara, Mirian& Ferrandez, Blanca& Otin, Sofia…[et al.]. 2014. Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients. BioMed Research International،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-477757

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Abadia, Beatriz…[et al.]. Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients. BioMed Research International No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-477757

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Abadia, Beatriz& Ferreras, Antonio L.& Calvo, Pilar& Ara, Mirian& Ferrandez, Blanca& Otin, Sofia…[et al.]. Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-477757

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-477757