A Blood Pressure Monitoring Method for Stroke Management
المؤلف
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-08-17
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
Blood pressure is one important risk factor for stroke prognosis.
Therefore, continuous monitoring of blood pressure is crucial for preventing and predicting stroke.
However, current blood pressure devices are mainly air-cuff based, which only can provide measurements intermittently.
This study proposed a new blood pressure estimation method based on the pulse transit time to realize continuous monitoring.
The proposed method integrated a linear model with a compensation algorithm.
A calibration method was further developed to guarantee that the model was personalized for individuals.
Variation and variability of pulse transit time were introduced to construct the compensation algorithm in the model.
The proposed method was validated by the data collected from 30 healthy subjects, aged from 23 to 25 years old.
By comparing the estimated value to the measurement from an oscillometry, the result showed that the mean error of the estimated blood pressure was -0.2±2.4 mmHg and 0.5±3.9 mmHg for systolic and diastolic blood pressure, respectively.
In addition, the estimation performance of the proposed model is better than the linear model, especially for the diastolic blood pressure.
The results indicate that the proposed method has promising potential to realize continuous blood pressure measurement.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ma, Heather Ting. 2014. A Blood Pressure Monitoring Method for Stroke Management. BioMed Research International،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-481685
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ma, Heather Ting. A Blood Pressure Monitoring Method for Stroke Management. BioMed Research International No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-481685
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ma, Heather Ting. A Blood Pressure Monitoring Method for Stroke Management. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-481685
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-481685
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر