Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting

المؤلفون المشاركون

Li, Lin
Song, Xudong
Yan, Yan
Wang, Ke
Liu, Zhicheng

المصدر

Computational and Mathematical Methods in Medicine

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-07-14

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

The tilt and decentration of intraocular lens (IOL) result in defocussing, astigmatism, and wavefront aberration after operation.

The objective is to give a method to estimate the tilt and decentration of IOL more accurately.

Based on AS-OCT images of twelve eyes from eight cases with subluxation lens after operation, we fitted spherical equation to the data obtained from the images of the anterior and posterior surfaces of the IOL.

By the established relationship between IOL tilt (decentration) and the scanned angle, at which a piece of AS-OCT image was taken by the instrument, the IOL tilt and decentration were calculated.

IOL tilt angle and decentration of each subject were given.

Moreover, the horizontal and vertical tilt was also obtained.

Accordingly, the possible errors of IOL tilt and decentration existed in the method employed by AS-OCT instrument.

Based on 6–12 pieces of AS-OCT images at different directions, the tilt angle and decentration values were shown, respectively.

The method of the surface fitting to the IOL surface can accurately analyze the IOL’s location, and six pieces of AS-OCT images at three pairs symmetrical directions are enough to get tilt angle and decentration value of IOL more precisely.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Li, Lin& Wang, Ke& Yan, Yan& Song, Xudong& Liu, Zhicheng. 2013. Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting. Computational and Mathematical Methods in Medicine،Vol. 2013, no. 2013, pp.1-7.
https://search.emarefa.net/detail/BIM-481778

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Li, Lin…[et al.]. Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting. Computational and Mathematical Methods in Medicine No. 2013 (2013), pp.1-7.
https://search.emarefa.net/detail/BIM-481778

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Li, Lin& Wang, Ke& Yan, Yan& Song, Xudong& Liu, Zhicheng. Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting. Computational and Mathematical Methods in Medicine. 2013. Vol. 2013, no. 2013, pp.1-7.
https://search.emarefa.net/detail/BIM-481778

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-481778