A New Device to Automate the Monitoring of Critical Patients’ Urine Output
المؤلفون المشاركون
Armada, Manuel
Apalkov, Andrey
Fernández, Roemi
Otero, Abraham
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-01-28
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Urine output (UO) is usually measured manually each hour in acutely ill patients.
This task consumes a substantial amount of time.
Furthermore, in the literature there is evidence that more frequent (minute-by-minute) UO measurement could impact clinical decision making and improve patient outcomes.
However, it is not feasible to manually take minute-by-minute UO measurements.
A device capable of automatically monitoring UO could save precious time of the healthcare staff and improve patient outcomes through a more precise and continuous monitoring of this parameter.
This paper presents a device capable of automatically monitoring UO.
It provides minute by minute measures and it can generate alarms that warn of deviations from therapeutic goals.
It uses a capacitive sensor for the measurement of the UO collected within a rigid container.
When the container is full, it automatically empties without requiring any internal or external power supply or any intervention by the nursing staff.
In vitro tests have been conducted to verify the proper operation and accuracy in the measures of the device.
These tests confirm the viability of the device to automate the monitoring of UO.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Otero, Abraham& Apalkov, Andrey& Fernández, Roemi& Armada, Manuel. 2014. A New Device to Automate the Monitoring of Critical Patients’ Urine Output. BioMed Research International،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-483064
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Otero, Abraham…[et al.]. A New Device to Automate the Monitoring of Critical Patients’ Urine Output. BioMed Research International No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-483064
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Otero, Abraham& Apalkov, Andrey& Fernández, Roemi& Armada, Manuel. A New Device to Automate the Monitoring of Critical Patients’ Urine Output. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-483064
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-483064
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر