Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients : A Pilot Study
المؤلفون المشاركون
González-Sánchez, Manuel
Merchán-Baeza, Jose Antonio
Cuesta-Vargas, Antonio Ignacio
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-04-29
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Background.
Postural instability is one of the major complications found in stroke survivors.
Parameterising the functional reach test (FRT) could be useful in clinical practice and basic research.
Objectives.
To analyse the reliability, sensitivity, and specificity in the FRT parameterisation using inertial sensors for recording kinematic variables in patients who have suffered a stroke.
Design.
Cross-sectional study.
While performing FRT, two inertial sensors were placed on the patient’s back (lumbar and trunk).
Participants.
Five subjects over 65 who suffer from a stroke.
Measurements.
FRT measures, lumbosacral/thoracic maximum angular displacement, maximum time of lumbosacral/thoracic angular displacement, time return initial position, and total time.
Speed and acceleration of the movements were calculated indirectly.
Results.
FRT measure is 12.75±2.06 cm.
Intrasubject reliability values range from 0.829 (time to return initial position (lumbar sensor)) to 0.891 (lumbosacral maximum angular displacement).
Intersubject reliability values range from 0.821 (time to return initial position (lumbar sensor)) to 0.883 (lumbosacral maximum angular displacement).
FRT’s reliability was 0.987 (0.983–0.992) and 0.983 (0.979–0.989) intersubject and intrasubject, respectively.
Conclusion.
The main conclusion could be that the inertial sensors are a tool with excellent reliability and validity in the parameterization of the FRT in people who have had a stroke.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Merchán-Baeza, Jose Antonio& González-Sánchez, Manuel& Cuesta-Vargas, Antonio Ignacio. 2014. Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients : A Pilot Study. BioMed Research International،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-487157
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Merchán-Baeza, Jose Antonio…[et al.]. Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients : A Pilot Study. BioMed Research International No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-487157
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Merchán-Baeza, Jose Antonio& González-Sánchez, Manuel& Cuesta-Vargas, Antonio Ignacio. Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients : A Pilot Study. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-487157
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-487157
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر