Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients : A Pilot Study

المؤلفون المشاركون

González-Sánchez, Manuel
Merchán-Baeza, Jose Antonio
Cuesta-Vargas, Antonio Ignacio

المصدر

BioMed Research International

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-04-29

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الطب البشري

الملخص EN

Background.

Postural instability is one of the major complications found in stroke survivors.

Parameterising the functional reach test (FRT) could be useful in clinical practice and basic research.

Objectives.

To analyse the reliability, sensitivity, and specificity in the FRT parameterisation using inertial sensors for recording kinematic variables in patients who have suffered a stroke.

Design.

Cross-sectional study.

While performing FRT, two inertial sensors were placed on the patient’s back (lumbar and trunk).

Participants.

Five subjects over 65 who suffer from a stroke.

Measurements.

FRT measures, lumbosacral/thoracic maximum angular displacement, maximum time of lumbosacral/thoracic angular displacement, time return initial position, and total time.

Speed and acceleration of the movements were calculated indirectly.

Results.

FRT measure is 12.75±2.06 cm.

Intrasubject reliability values range from 0.829 (time to return initial position (lumbar sensor)) to 0.891 (lumbosacral maximum angular displacement).

Intersubject reliability values range from 0.821 (time to return initial position (lumbar sensor)) to 0.883 (lumbosacral maximum angular displacement).

FRT’s reliability was 0.987 (0.983–0.992) and 0.983 (0.979–0.989) intersubject and intrasubject, respectively.

Conclusion.

The main conclusion could be that the inertial sensors are a tool with excellent reliability and validity in the parameterization of the FRT in people who have had a stroke.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Merchán-Baeza, Jose Antonio& González-Sánchez, Manuel& Cuesta-Vargas, Antonio Ignacio. 2014. Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients : A Pilot Study. BioMed Research International،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-487157

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Merchán-Baeza, Jose Antonio…[et al.]. Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients : A Pilot Study. BioMed Research International No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-487157

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Merchán-Baeza, Jose Antonio& González-Sánchez, Manuel& Cuesta-Vargas, Antonio Ignacio. Reliability in the Parameterization of the Functional Reach Test in Elderly Stroke Patients : A Pilot Study. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-487157

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-487157