Interrater Reproducibility of Knee Movement Analyses during the Stance Phase : Use of Anatomical Landmark Calibration with a Rigid Marker Set

المؤلفون المشاركون

Mutsuzaki, Hirotaka
Wadano, Yasuyoshi
Fukaya, Takashi

المصدر

Rehabilitation Research and Practice

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-10-03

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Objective.

Measurements of knee joint movement in gait analysis may result in large errors caused by misplacement of reflective markers by the testers.

To properly understand the measurement results, it is important to guarantee the reliability of the measurement method used for the purpose.

The aim of this study was to confirm the interrater reproducibility of a measurement method with a rigid marker set (RMS).

Methods.

The study subjects were four healthy adults, and the testers were three physical therapists.

The interrater reproducibility of the measurements was verified by using the coefficient of multiple correlations (CMCs) and the standard error of measurement (SEM).

Results.

The average CMCs values of 4 subjects in knee joint movement at the stance phase were greater than 0.8, and the average SEM values of 4 subjects in knee joint movement at the stance phase were also relatively good (maximum error: 2.42°).

Conclusion.

Based on these results, the measurement method with estimation of anatomical landmarks using the RMS can prevent misplacement during attachment of the reflective markers, as long as the testers have sufficient experience in attaching reflective markers.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Fukaya, Takashi& Mutsuzaki, Hirotaka& Wadano, Yasuyoshi. 2013. Interrater Reproducibility of Knee Movement Analyses during the Stance Phase : Use of Anatomical Landmark Calibration with a Rigid Marker Set. Rehabilitation Research and Practice،Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-491025

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Fukaya, Takashi…[et al.]. Interrater Reproducibility of Knee Movement Analyses during the Stance Phase : Use of Anatomical Landmark Calibration with a Rigid Marker Set. Rehabilitation Research and Practice No. 2013 (2013), pp.1-5.
https://search.emarefa.net/detail/BIM-491025

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Fukaya, Takashi& Mutsuzaki, Hirotaka& Wadano, Yasuyoshi. Interrater Reproducibility of Knee Movement Analyses during the Stance Phase : Use of Anatomical Landmark Calibration with a Rigid Marker Set. Rehabilitation Research and Practice. 2013. Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-491025

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-491025