![](/images/graphics-bg.png)
Biomechanical Study of the Pullout Resistance in Screws of a Vertebral Fixation System
المؤلفون المشاركون
Zamarioli, Ariane
Shimano, Antonio Carlos
Aparecido Defino, Helton Luiz
Araujo, Cleudmar Amaral
Fakhouri, Sarah Fakher
Wichr, Célia R. G.
المصدر
Advances in Mechanical Engineering
العدد
المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2011-10-15
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
The purpose of this study was to investigate the effect of varying the outer diameter of screws of a vertebral fixation system by submitting them to mechanical tests and photoelasticity.
The pullout mechanical test was performed in 20 swine lumbar vertebrae, divided into two groups based on the screw outer diameter: 5.0 and 6.0 mm.
The maximal pullout strengths and stiffness were evaluated.
For the photoelasticity, eight models were used and divided into the same groups.
The maximal pullout strength was 974.12 ± 144.44 N in the 5.0 mm screws and 1537.42 ± 326.95 N in the 6.0 mm screws (P < 0.001).
The stiffness was 418.60 ± 62.58 103N/m in the 5.0 mm screws and 502.12 ± 133.45 103N/m in the 6.0 mm screws (P = 0.09).
The mean ± SD shear stress of the 5.0 mm screws was 12.90 ± 1.87 KPa and 11.99 ± 2.01 KPa for the 6.0 mm screws.
Thus, the 5.0 mm screw had lower pullout and higher shear stress, suggesting that this screw is more susceptible to loosening.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Fakhouri, Sarah Fakher& Zamarioli, Ariane& Wichr, Célia R. G.& Araujo, Cleudmar Amaral& Aparecido Defino, Helton Luiz& Shimano, Antonio Carlos. 2011. Biomechanical Study of the Pullout Resistance in Screws of a Vertebral Fixation System. Advances in Mechanical Engineering،Vol. 2011, no. 2011, pp.1-6.
https://search.emarefa.net/detail/BIM-491610
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Fakhouri, Sarah Fakher…[et al.]. Biomechanical Study of the Pullout Resistance in Screws of a Vertebral Fixation System. Advances in Mechanical Engineering No. 2011 (2011), pp.1-6.
https://search.emarefa.net/detail/BIM-491610
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Fakhouri, Sarah Fakher& Zamarioli, Ariane& Wichr, Célia R. G.& Araujo, Cleudmar Amaral& Aparecido Defino, Helton Luiz& Shimano, Antonio Carlos. Biomechanical Study of the Pullout Resistance in Screws of a Vertebral Fixation System. Advances in Mechanical Engineering. 2011. Vol. 2011, no. 2011, pp.1-6.
https://search.emarefa.net/detail/BIM-491610
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-491610
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)