Reduction of Oxygen-Carrying Capacity Weakens the Effects of Increased Plasma Viscosity on Cardiac Performance in Anesthetized Hemodilution Model

المؤلفون المشاركون

Chatpun, Surapong
Cabrales, Pedro

المصدر

ISRN Anesthesiology

العدد

المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2012-07-19

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الأمراض

الملخص EN

We investigated the effects of reduced oxygen-carrying capacity on cardiac function during acute hemodilution, while the plasma viscosity was increased in anesthetized animals.

Two levels of oxygen-carrying capacity were created by 1-step and 2-step hemodilution in male golden Syrian hamsters.

In the 1-step hemodilution (1-HD), 40% of the animals' blood volume (BV) was exchanged with 6% dextran 70 kDa (Dx70) or dextran 2000 kDa (Dx2M).

In the 2-step hemodilution (2-HD), 25% of the animals' BV was exchanged with Dx70 followed by 40% BV exchanged with Dx70 or Dx2M after 30 minutes of first hemodilution.

Oxygen delivery in the 2-HD group consequently decreased by 17% and 38% compared to that in the 1-HD group hemodiluted with Dx70 and Dx2M, respectively.

End-systolic pressure and maximum rate of pressure change in the 2-HD group significantly lowered compared with that in the 1-HD group for both Dx70 and Dx2M.

Cardiac output in the 2-HD group hemodiluted with Dx2M was significantly higher compared with that hemodiluted with Dx70.

In conclusion, increasing plasma viscosity associated with lowering oxygen-carrying capacity should be considerably balanced to maintain the cardiac performance, especially in the state of anesthesia.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Chatpun, Surapong& Cabrales, Pedro. 2012. Reduction of Oxygen-Carrying Capacity Weakens the Effects of Increased Plasma Viscosity on Cardiac Performance in Anesthetized Hemodilution Model. ISRN Anesthesiology،Vol. 2012, no. 2012, pp.1-9.
https://search.emarefa.net/detail/BIM-491693

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Chatpun, Surapong& Cabrales, Pedro. Reduction of Oxygen-Carrying Capacity Weakens the Effects of Increased Plasma Viscosity on Cardiac Performance in Anesthetized Hemodilution Model. ISRN Anesthesiology No. 2012 (2012), pp.1-9.
https://search.emarefa.net/detail/BIM-491693

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Chatpun, Surapong& Cabrales, Pedro. Reduction of Oxygen-Carrying Capacity Weakens the Effects of Increased Plasma Viscosity on Cardiac Performance in Anesthetized Hemodilution Model. ISRN Anesthesiology. 2012. Vol. 2012, no. 2012, pp.1-9.
https://search.emarefa.net/detail/BIM-491693

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-491693