Dimensional Accuracy of Stone Casts Obtained with Multiple Pours into the Same Mold

المؤلفون المشاركون

de Moura, Carmem Dolores Vilarinho Soares
Pádua, Luiz Evaldo de Moura
Feltrin, Pedro Paulo
Valente, Valdimar da Silva
Zanetti, Artêmio Luiz
Inoue, Ricardo Tatsuo

المصدر

ISRN Dentistry

العدد

المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2012-12-24

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

طب الأسنان

الملخص EN

Aim.

The aim of the present study was to compare the dimensional accuracy of stone casts obtained with vinyl polysiloxane molds through the double-impression technique with three pours into the same mold.

Methods.

A stainless steel master model was constructed simulating a three-unit fixed prosthesis.

Twelve impressions were taken of this master model with addition silicone, using the double-impression technique.

Three pours of type IV gypsum were then made into each mold, thus producing 36 casts.

The pours were made 1 hour, 6 hours and 24 hours after the impression procedure.

Next, intra- and interabutment measurements were made in a coordinate measuring machine.

Results.

Comparative analysis of the dimensional accuracy of stone casts resulting from multiple pours was not statistically significant in pours first and second (P>0.05).

These values, however, were statistically significant at third pour in the height in abutment 1 and upper distance interabutment.

Conclusion.

The wait time (1 hour, and 6 hours) observed before pouring the stone into the same molds did not cause significant dimensional accuracy of the casts.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Valente, Valdimar da Silva& Zanetti, Artêmio Luiz& Feltrin, Pedro Paulo& Inoue, Ricardo Tatsuo& de Moura, Carmem Dolores Vilarinho Soares& Pádua, Luiz Evaldo de Moura. 2012. Dimensional Accuracy of Stone Casts Obtained with Multiple Pours into the Same Mold. ISRN Dentistry،Vol. 2012, no. 2012, pp.1-5.
https://search.emarefa.net/detail/BIM-494130

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Valente, Valdimar da Silva…[et al.]. Dimensional Accuracy of Stone Casts Obtained with Multiple Pours into the Same Mold. ISRN Dentistry No. 2012 (2012), pp.1-5.
https://search.emarefa.net/detail/BIM-494130

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Valente, Valdimar da Silva& Zanetti, Artêmio Luiz& Feltrin, Pedro Paulo& Inoue, Ricardo Tatsuo& de Moura, Carmem Dolores Vilarinho Soares& Pádua, Luiz Evaldo de Moura. Dimensional Accuracy of Stone Casts Obtained with Multiple Pours into the Same Mold. ISRN Dentistry. 2012. Vol. 2012, no. 2012, pp.1-5.
https://search.emarefa.net/detail/BIM-494130

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-494130