Ignition of Free Gas in the Peritoneal Cavity : An Explosive Complication

المؤلفون المشاركون

Mumith, Aadil
Gurunathan-Mani, Sivaraman
Thuraisingham, Justin

المصدر

Case Reports in Surgery

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-2، 2ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-01-29

دولة النشر

مصر

عدد الصفحات

2

التخصصات الرئيسية

الطب البشري

الملخص EN

We report an extremely rare event where the use of diathermy to enter the peritoneal cavity caused the free gas within it to ignite and consequently burn the surgeon during a standard right hemicolectomy procedure for a caecal perforation.

This should be noted as a possible safety concern intraoperatively.

We conclude that sharp dissection should always be used initially when entering the peritoneal cavity where free gas is present, cautery can subsequently be used once the free air has escaped.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Mumith, Aadil& Thuraisingham, Justin& Gurunathan-Mani, Sivaraman. 2013. Ignition of Free Gas in the Peritoneal Cavity : An Explosive Complication. Case Reports in Surgery،Vol. 2013, no. 2013, pp.1-2.
https://search.emarefa.net/detail/BIM-495415

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Mumith, Aadil…[et al.]. Ignition of Free Gas in the Peritoneal Cavity : An Explosive Complication. Case Reports in Surgery No. 2013 (2013), pp.1-2.
https://search.emarefa.net/detail/BIM-495415

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Mumith, Aadil& Thuraisingham, Justin& Gurunathan-Mani, Sivaraman. Ignition of Free Gas in the Peritoneal Cavity : An Explosive Complication. Case Reports in Surgery. 2013. Vol. 2013, no. 2013, pp.1-2.
https://search.emarefa.net/detail/BIM-495415

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-495415