Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones
المؤلفون المشاركون
Gironi Carnevale, Ugo Antonello
Bifani, Mario
Lanza, Michele
Cennamo, Michela
Irregolare, Carlo
Iaccarino, Stefania
Rechichi, Miguel
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-06-23
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
This study was designed to evaluate the correlation between corneal biomechanical and morphological data in healthy eyes, eyes that underwent myopic photorefractive keratectomy (PRK), keratoconus affected eyes, and keratoconus affected eyes that underwent corneal collagen crosslinking (CCC).
Complete clinical eye examination of all eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Germany) and biomechanical (Corvis ST, Oculus, Wetzlar, Germany) evaluation.
Differences among Corvis ST (CST) parameters in the different groups have been performed.
Linear regression between central corneal thickness (CCT), intraocular pressure (IOP), and anterior corneal curvature measured with Sim’K (KM), versus corneal deformation parameters measured with Corvis ST in the different groups, has been run using SPSS software version 18.0.
We evaluated 64 healthy eyes of 64 patients with a mean refractive error of -0.65±1.68 D (measured as spherical equivalent), 17 eyes of 17 patients that underwent myopic PRK for a mean refractive defect of -4.91±2.05 D (measured as spherical equivalent), 16 eyes of 16 patients affected by keratconus (stage 2-3 of Amsler Classification), and 13 eyes of 13 patients affected by keratoconus that underwent CCC.
Our data suggest that corneal curvature would have a greater influence on corneal deformation than CCT; in fact KM values are more strongly associated with more CST parameters both about corneal change in shape and both about the corneal ability to come back at original shape.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Lanza, Michele& Cennamo, Michela& Iaccarino, Stefania& Irregolare, Carlo& Rechichi, Miguel& Bifani, Mario…[et al.]. 2014. Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones. BioMed Research International،Vol. 2014, no. 2014, pp.1-9.
https://search.emarefa.net/detail/BIM-495605
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Lanza, Michele…[et al.]. Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones. BioMed Research International No. 2014 (2014), pp.1-9.
https://search.emarefa.net/detail/BIM-495605
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Lanza, Michele& Cennamo, Michela& Iaccarino, Stefania& Irregolare, Carlo& Rechichi, Miguel& Bifani, Mario…[et al.]. Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-9.
https://search.emarefa.net/detail/BIM-495605
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-495605
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)