Purpose.

To determine whether in vivo proton magnetic resonance spectroscopy at 3T can provide accurate breast lesion characterization, and to determine the effect of gadolinium on the resonance of tCho.

Methods.

Twenty-four positive-mammogram patients were examined on a 3T MR scanner.

1H-MRS was performed before and after gadolinium administration.

tCho peak was qualitatively evaluated before and after contrast injection.

Results.

Fourteen out of 27 lesions proved to be malignant after histopathological diagnosis.

Using 1H-MRS, before contrast injection, 6/14 confirmed malignancies and 11/13 benign lesions were correctly classified; while, after contrast injection, 11/14 confirmed malignancies and 12/13 benign processes were correctly classified.

Post gadolinium 1H-MRS proved useful in picking up tCho signal, improving the overall accuracy, sensitivity, and specificity by 35%, 83%, and 9%, respectively.

Conclusion.

1H-MRS overall accuracy, sensitivity, and specificity in detecting breast lesion’s malignancy were increased after gadolinium administration.

It is prudent to perform 1H-MRS before contrast injection in large breast lesions to avoid choline underestimation.

In cases of small or non-mass lesions, it is recommended to perform 1H-MRS after contrast injection for better voxel prescription to enable a reliable preoperative diagnosis.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Kousi, E.& Tsougos, I.& Vasiou, K.& Theodorou, Kiki& Poultsidi, A.& Fezoulidis, Ioannis…[et al.]. 2012. Magnetic Resonance Spectroscopy of the Breast at 3T : Pre- and Post-Contrast Evaluation for Breast Lesion Characterization. The Scientific World Journal،Vol. 2012, no. 2012, pp.1-9.
https://search.emarefa.net/detail/BIM-496155

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Kousi, E.…[et al.]. Magnetic Resonance Spectroscopy of the Breast at 3T : Pre- and Post-Contrast Evaluation for Breast Lesion Characterization. The Scientific World Journal No. 2012 (2012), pp.1-9.
https://search.emarefa.net/detail/BIM-496155

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Kousi, E.& Tsougos, I.& Vasiou, K.& Theodorou, Kiki& Poultsidi, A.& Fezoulidis, Ioannis…[et al.]. Magnetic Resonance Spectroscopy of the Breast at 3T : Pre- and Post-Contrast Evaluation for Breast Lesion Characterization. The Scientific World Journal. 2012. Vol. 2012, no. 2012, pp.1-9.
https://search.emarefa.net/detail/BIM-496155

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-496155